Appendix F Using a PHD
product information for the PHD application appears. Press
F3
(Scan
Counts) to see the number of scans in of each feature.
Important:
The PHD can store up to 4,000 scans for
each
feature.
However, we recommend that you upload the scans to a workstation
after gathering 1,200 for a feature to minimize any possible loss due to
mechanical or user error.
Erasing scans
As soon as you've sent the barcode scans in your PHD to a workstation, if you
don't need them for another process, we recommend that you erase them from
your PHD. The PHD provides you with two options for erasing
scanned barcodes:
To erase
only
the barcode scans for a particular feature, go to that feature's
menu and press
F4
(Erase <FEATURE> scans). A message appears asking
you to confirm your choice. To delete the scans for the feature, press
ENTER
(Yes). After deleting the scans, the PHD displays a brief confirmation.
To erase
all
the barcode scans in your PHD, from the main menu press
F4
(Setup), then press
F4
(Utilities) from the Setup Menu. The Utilities Menu
appears. Press
F4
(Erase ALL scans). A message appears asking you to
confirm your choice. To delete all the scans in your PHD, press
ENTER
(Yes).
After deleting all the scans, the PHD displays a brief confirmation.
Troubleshooting
When attempting to send scans from, or load the application to, the Dolphin,
error messages may appear in the computer window, the Dolphin LCD screen, or
the Dolphin File Transfer dialog (on the computer). The following table contains
some of the error messages that may appear and the procedure to follow. It also
includes instructions for rebooting your Dolphin. Rebooting the Dolphin or
loading the application does
not
erase any scans stored in the Dolphin.
Message
Cause / Solution
Bytes:
Blocks:
Errors: <number>
MSG: Timeout
(on the Dolphin screen)
The Dolphin is attempting to contact the Follett
application but is receiving no reply.
You may not have clicked Update, Delete, Proceed, Load,
or Download on the computer after pressing
F3
-Send on
the Dolphin. Click the button on the computer window
while the Errors counter is still incrementing.
Or, a physical connection does not exist. Check all
hardware connections.
C:\>
(on the Dolphin screen)
The loading of the PHD application did not complete.
Reboot the Dolphin by simultaneously pressing and
releasing the
ON SCAN
,
SHIFT
, and
BKSP
keys.
If the message to load the application appears, do so.
If the main menu appears, you can resume normal use.
If another
C:\>
appears, follow the instructions for
DOS0011: Invalid Format
below.
Содержание VERSION 6.00
Страница 8: ...8 04 04 Notes...
Страница 60: ...04 04 60 System Setup Notes...
Страница 68: ...04 04 68 System Setup Notes...
Страница 114: ...04 04 114 System Setup Notes...
Страница 146: ...04 04 146 Circulation Desk Notes...
Страница 216: ...04 04 216 Inventory Notes...
Страница 254: ...04 04 254 Cataloging Notes...
Страница 322: ...04 04 322 Cataloging Notes...
Страница 370: ...04 04 370 Cataloging Notes...
Страница 394: ...04 04 394 Alliance Plus Notes...
Страница 402: ...04 04 402 Alliance Plus Notes...
Страница 430: ...04 04 430 Search Stations Notes...
Страница 498: ...04 04 498 Reports Notes...
Страница 590: ...04 04 590 Reports Notes...
Страница 642: ...04 04 642 Appendices Notes...
Страница 698: ...04 04 698 Appendices Notes...
Страница 726: ...04 04 726 Index...
Страница 728: ......
Страница 729: ......
Страница 730: ...The User s Guide v6 00 04 04 A 40800A 730...