Installation
Before you begin
§
All dispensers must be installed level in both directions to ensure proper operation .
§
Service and ventilation clearances: 6" (15 .3 cm) on right side of dispenser, 6" (15 .3 cm) at top for ventilation and
12" (30 .5 cm) at top recommended for service .
§
Countertop units installed without legs provide the option of taking utilities out bottom or back of dispenser (on
wall mount units and countertop units with legs, utilities exit from back) . See counter cutout drawings for bottom
exiting utilities on units with and without drain pans . For installations where utilities exit through back of dispenser,
refer to back view drawings .
§
Counter depth must allow front of sink to be a minimum of 30 .00" (76 .2 cm) from wall .
Installing countertop dispensers without
legs
1. Position dispenser in desired location, mark
dispenser outline on counter and remove
dispenser .
2. Regardless of whether utilities will exit
through back or bottom of dispenser, drill
four (4) 7/16" holes in counter to anchor
dispenser to counter
(Fig. 1) .
3. For utilities exiting through bottom only:
(a) Make cut out as shown in
Fig. 1.
(b) Move drain fitting from back of dispenser and
mount where shown in
Fig. 2 .
(c) Cut drain tube to length and attach to barbed
connection .
(d) Move inlet water fitting from back of
dispenser and mount where shown in
Fig. 2 .
(e) Cut water tubing to length and re-insert into
water fitting .
4. For all units: Apply a thick bead
approximately 1/4" (6 mm) diameter of
NSF-listed silicone sealant (Dow Corning
RTV-732* or equivalent) 1/4" (6 mm) inside
marked outline of dispenser .
5. Carefully lower dispenser on counter in
proper position and secure to counter with
four (4) 3/8"-16UNC bolts .
6. Smooth excess sealant around outside of
dispenser .
Fig. 1
2.00"
(5.1 cm)
12.00"
(30.5 cm)
14.37"
(36.5 cm)
4X
Ø.437"
(11 mm)
hole
1.04"
(2.6 cm)
16.00"
(40.7 cm)
Cutout
connections
through
bottom
12.00"
(30.5 cm)
0.81"
(2.1 cm)
16.00"
(40.7 cm)
1.50"
(3.8 cm)
17.87"
(45.4 cm)
5.62"
(14.3 cm)
Fig. 2 - Bottom exiting utilities (countertop units)
bracket
inlet
fitting
drain
fitting
drain tube
E12CI425A 230 V 50 Hz, C12CI425A 220 V 60 Hz 5