Refrigeration pressure data
Air-Cooled ice machine capacity/24hrs – 220 V/60 Hz
Ambient Air Temperature F/C
Inlet
W
at
er T
emper
atur
e
F/C
F
60
70
80
90
100
C
16
21
27
32
38
50
418
388
357
325
294
lbs .
10
189
176
162
147
179
kg .
60
395
370
345
313
281
lbs .
16
179
168
156
142
127
kg .
70
372
353
334
301
268
lbs .
21
169
160
151
137
122
kg .
80
362
340
318
288
259
lbs .
27
164
154
144
131
117
kg .
90
352
327
302
275
249
lbs .
32
160
148
137
125
113
kg .
Air-Cooled ice machine capacity/24hrs – 230 V/50 Hz
Ambient Air Temperature F/C
Inlet
W
at
er T
emper
atur
e
F/C
F
60
70
80
90
100
C
16
21
27
32
38
50
429
401
374
341
308
lbs .
10
195
182
170
155
140
kg .
60
407
381
355
324
293
lbs .
16
185
173
161
147
133
kg .
70
385
360
336
307
278
lbs .
21
175
163
152
139
126
kg .
80
369
346
323
295
267
lbs .
27
167
157
147
134
121
kg .
90
354
332
310
283
255
lbs .
32
161
151
141
128
116
kg .
Compressor data
Air-cooled
Ambient air temperature
60 F/15.6 C
70 F/21.1 C
80 F/26.7 C
90 F/32.2 C
100 F/37.8 C
220 V
230 V
220 V
230 V
220 V
230 V
220 V
230 V
220 V
230 V
Amperage
2 .7
2 .2
2 .8
2 .3
2 .9
2 .5
3 .0
2 .6
3 .1
2 .8
High-side pressure (psi)
210
197
247
235
285
273
322
311
360
349
Low-side pressure (psi)
27
28
29
30
31
32
33
34
35
36
Locked rotor amps
220 V: 19 .6A
230 V: 18 .2A
Gearmotor data
Gearmotor current
220 V: 1 .A (nominal)
230 V: 1 .3A (nominal)
Locked rotor amps
6 .8A
6 .8A
Refrigeration system
Important: All service on refrigeration system must be performed in accordance with all federal, state and
local laws that pertain to the use of refrigerants . It is the responsibility of the technician to ensure that these
requirements are met .
R425 ice machine charge specifications
Model
Charge
Refrigerant type
C/E12CI425A (air-cooled)
15 oz
R404A
CAUTION!
§
Recharging of unit at other than factory specifications will void ice machine warranty .
32
E12CI425A 230 V 50 Hz, C12CI425A 220 V 60 Hz