background image

Self-flushing (when enabled)

At the completion of the 20 minute time delay, the machine checks for a cumulative one hour of ice making time 

since the last off-cycle flush . If the cumulative ice making time exceeds one hour, the machine will energize the 

drain valve P19 for 60 seconds to drain the evaporator . It will then refill with water, flush again, refill and begin 

making ice if the 

LOW BIN LED is on . If the ice making time is less than 1 hour, the machine will start and begin 

making ice without draining the evaporator .

Start 

Run 

Compressor 

T.O.L. 

MAINTENANCE 

LOW WATER 

TIME DELAY 

SLEEP CYCLE 

MAKING ICE 

LOW BIN 

POWER 

SERVICE 

HI AMPS 

HI PRESSURE 

DRAIN CLOG 

CLEANER FULL 

High 

Pressure 

Switch 

R S 

Gearmotor 

Start 

Relay 

Start 

Relay 

L1 

Fan 

A  B  C  D 

Water Sensors 

RESET 

Fill 

Valve 

Drain 

Valve 

Bin T-Stat 

Clean Switch 

Drain Clog Sensor 

P6 
P21 
P20 
P19 
P3 
P22 

P4 

AUGER 

WATER LEVELS 

BIN  P11 

HI PRS 

L1 

RED 

WHITE 

WHITE 

BLACK 

BROWN 

BLUE 

RED 

BLACK 

YELLOW 

Compressor 

Electrical Box 

COMPRESSOR 

1 2 3 4 5 6 7 8 

BLACK 

P15 

Ice Dispense Input

Capacitor

BLACK

YELLOW

OR

NO CONNECT

Diagnostic Stages

High gearmotor amps – Stage 1

The 

HI AMPS error and TIME DELAY LEDs are on indicating that the control board has sensed an over-torque 

condition at the P4 terminal (more than 3 amps from the gearmotor) or no current draw (0A) and shut the ice 

machine down (strike one) . The 

HI AMPS and TIME DELAY LEDs will remain on for 60 minutes after an over-

torque condition has occurred . The ice machine will remain off as long as these two LEDs are on . After the 

60 minute time delay, these LED lights turn off, and the control board will try to go through a normal start-up 

sequence .

Capacitor

BLACK

YELLOW

Start 

Run 

Compressor 

T.O.L. 

MAINTENANCE 

LOW WATER 

TIME DELAY 

SLEEP CYCLE 

MAKING ICE 

LOW BIN 

POWER 

SERVICE 

HI AMPS 

HI PRESSURE 

DRAIN CLOG 

CLEANER FULL 

High 

Pressure 

Switch 

R S 

Gearmotor 

Start 

Relay 

Start 

Relay 

L1 

Fan 

A  B  C  D 

Water Sensors 

RESET 

Fill 

Valve 

Drain 

Valve 

Bin T-Stat 

Clean Switch 

Drain Clog Sensor 

P6 

P21 
P20 
P19 

P3 
P22 

P4 

AUGER 

WATER LEVELS 

BIN  P11 

HI PRS 

L1 

RED 

WHITE 

WHITE 

BLACK 

BROWN 

BLUE 

RED 

BLACK 

YELLOW 

Compressor 

Electrical Box 

COMPRESSOR 

1 2 3 4 5 6 7 8 

BLACK 

P15 

Ice Dispense Input

OR

NO CONNECT

20 

MCD425A/W, R425A/W, MFD425A/W, P425A/W Ice Machines

Содержание MCD425A/W

Страница 1: ...04 801 Church Lane Easton PA 18040 USA Toll free 877 612 5086 1 610 252 7301 www follettice com Operation and Service Manual MCD425A W R425A W MFD425A W P425A W Ice Machines Following installation ple...

Страница 2: ...2 MCD425A W R425A W MFD425A W P425A W Ice Machines...

Страница 3: ...ate 7 Service 9 Ice machine Operation all models 9 Water system 10 Electrical system 11 Technical specifications all models 13 Electrical control system schematic 14 Electrical control system operatio...

Страница 4: ...to provide information about the type and capacity of Follett equipment Following is an explanation of the different model numbers in the 425 series Important cautions Moving parts Do not operate wit...

Страница 5: ...ndenser To prevent back flow do NOT connect drains Follett recommends a Follett water filter system be installed in the ice machine inlet water line standard capacity 00130229 high capacity 00978957 c...

Страница 6: ...88 48 cm 18 88 48 cm 2 32 5 9 cm 4 40 11 2 cm 15 22 38 7 cm 11 03 28 0 cm 8 03 20 4 cm 5 03 12 8 cm 2 34 6 cm Dimensions and clearances Entire front of ice machine must be clear of obstructions connec...

Страница 7: ...ed according to the schedule below Service problems resulting from lack of preventive maintenance will not be covered under the Follett warranty Symphony Plus Frequency Drain Line weekly Drain Pan Dri...

Страница 8: ...6 CLEANER FULL light will turn on and machine will start cleaning cycle then rinse three times this process takes approximately 15 minutes 7 When machine is finished cleaning the MAINTENANCE light wil...

Страница 9: ...he water supply when the ice machine is not running When the ice machine is running a layer of ice forms on the interior surface of the evaporator This ice is continuously removed by a slowly rotating...

Страница 10: ...l until the Normal Low sensor is exposed triggering the water feed solenoid on Water will fill until the Normal High sensor is activated Note The potable water dissolved solids content must be greater...

Страница 11: ...initiating the time delay period When the time delay expires the machine will restart provided that the LOW BIN light is on DIP Switch Settings Sleep cycle dispense duration OFF ON 1 2 3 4 5 6 7 8 4 5...

Страница 12: ...the water be shut off to a running machine a soft error will occur The error sequence is as follows During operation the water level falls to the normal low sensor and when it does the water feed sole...

Страница 13: ...d Ambient air temperature 60 F 15 6 C 70 F 21 1 C 80 F 26 7 C 90 F 32 2 C 100 F 37 8 C Amperage 6 3A 6 5A 6 7A 6 9A 7 1A High side pressure psi 190 220 250 290 330 Low side pressure psi 27 29 31 33 36...

Страница 14: ...T SENS RESET PROGRAM P5 ICE AUX WATER AUX D9 D8 D7 D6 D5 D4 D37 D3 D2 D18 D16 D15 D14 D13 D12 D11 D10 D1 T1 P18 P11 P13 P17 P12 P14 P16 P15 P4 T2 S1 S2 K1 P7 P8 P10 K3 1 2 6 5 P9 L1 L1 L1 N N N N N N...

Страница 15: ...the unit containing the split phase gear motor Normal operation Stage 1 Power is supplied to L1 of the control board the POWER LED light begins flashing The ice level bin thermostat in the dispenser...

Страница 16: ...5 6 7 8 BLACK N P15 I c e D i s p e n s e I n p u t Capacitor BLACK YELLOW OR NO CONNECT PSC Start winding energized through capacitor Normal operation Stage 3 After the initial high current draw dro...

Страница 17: ...BLACK YELLOW OR NO CONNECT Normal operation Stage 5 As the compressor comes up to normal running speed its start winding generates a voltage potential across the relay s coil This energizes the coil t...

Страница 18: ...YELLOW OR NO CONNECT Normal operation Stage 7 The fan motor continues for 10 minutes before shutting off The TIME DELAY LED remains on for 20 minutes The ice machine will not start while the TIME DEL...

Страница 19: ...Sensor P6 P21 P20 P19 P3 P22 P4 AUGER WATER LEVELS BIN P11 HI PRS L1 R S C RED WHITE WHITE BLACK BROWN BLUE RED BLACK YELLOW Compressor Electrical Box COMPRESSOR 1 2 3 4 5 6 7 8 BLACK N P15 I c e D i...

Страница 20: ...p u t Capacitor BLACK YELLOW OR NO CONNECT Diagnostic Stages High gearmotor amps Stage 1 The HI AMPS error and TIME DELAY LEDs are on indicating that the control board has sensed an over torque condi...

Страница 21: ...OR NO CONNECT High gearmotor amps Stage 3 If a second occurrence happens during the 60 minute monitoring period the HI AMPS LED will come on again and shut the machine down strike two The HI AMPS LED...

Страница 22: ...OW WATER LED will remain ON until the water level is satisfied 5 2 1 Start Run Compressor T O L MAINTENANCE LOW WATER TIME DELAY SLEEP CYCLE MAKING ICE LOW BIN POWER SERVICE HI AMPS HI PRESSURE DRAIN...

Страница 23: ...P6 P21 P20 P19 P3 P22 P4 AUGER WATER LEVELS BIN P11 HI PRS L1 R S C RED WHITE WHITE BLACK BROWN BLUE RED BLACK YELLOW Compressor Electrical Box COMPRESSOR 1 2 3 4 5 6 7 8 BLACK N P15 I c e D i s p e n...

Страница 24: ...n does not approve of recovered refrigerants Improper refrigeration servicing procedures will void the factory warranty Evacuation Evacuate the system to a level of 500 microns When the 500 micron lev...

Страница 25: ...r 11 Lift auger straight up and out of evaporator 12 Remove nut and lower vee band coupling from bottom of evaporator 13 Lift evaporator to clear bottom bearing assembly 14 Loosen hex head bolt in sid...

Страница 26: ...ll upper bearing and seal assembly rotating bearing to slip pin into auger slot 13 Install upper vee band clamp and nut to 70 in lb 14 Install evaporator insulation 15 Install compression nozzle and t...

Страница 27: ...eries with air cooled ice machines MCD425A All VU300 series with water cooled ice machines MCD425W Freestanding dispensers with ice machines in the base 25FB425A P425A 25FB425W P425W 50FB425A P425A 50...

Страница 28: ...Duct including gasket 01068188 3 Front panel 01068204 4 Spacer base 01068220 5 Panel right side 01068238 6 Panel left side and rear 1 piece 01068246 7 Bushing 01026152 8 Panel top 01068253 9 Tube dra...

Страница 29: ...condenser 00195966 2 Fitting water 01065375 3 Fitting drain 00109728 4 Panel front 01068261 5 Spacer base 01068220 6 Panel right side 01068238 7 Tube drain 01016948 8 Panel left side and rear 1 piece...

Страница 30: ...425A W MFD425A W P425A W Ice Machines Louvered docking station MCD425A W_T 1 2 3 4 Reference Description Part 1 Louver front 01006154 2 Cover front 01068279 3 Tube drain 01055185 4 Lovered docking sta...

Страница 31: ...Hz 01064708 4 Switch clean 00117036 Not shown Bin thermostat MCD425A WBT MCD425A WHT MFD425A WBT and MFD425A WHT only 500514 Not shown Board stand off control 8 required 00903005 Not shown Relay power...

Страница 32: ...D425A W R425A W MFD425A W P425A W Ice Machines Evaporator FOOD SERVICE HEALTHCARE FLAKER FLAKER COMPONENTS 27 15 17 25 1 3 4 5 20 19 7 6 8 10 11 12 16 9 22 21 1 17 18 18 26 24 2 28 23 32 3 4 29 13 13...

Страница 33: ...in 01064674 16 Drain pan evaporator 00181990 17 Tube compression nozzle vent 01027804 18 Tube compression nozzle single drain 01027416 Not shown Grease Chevron SRI 2 14 oz 501111 19 Bracket vent hoses...

Страница 34: ...34 MCD425A W R425A W MFD425A W P425A W Ice Machines Air cooled ice machines 2 15 21 3 12 20 7 6 10 22 17 16 9 13 1 14 8 18 19 5 4 11 23 24 25...

Страница 35: ...98765 13 Fan blade 500474 14 Motor fan 115 V 60 Hz 500672 15 Bracket fan motor 01067107 Not shown Overload compressor 115 V 60 Hz 01027572 16 Compressor 115 V 60 Hz 01065259 17 Tube fill purge reservo...

Страница 36: ...36 MCD425A W R425A W MFD425A W P425A W Ice Machines Water cooled ice machines 14 18 2 3 17 19 20 4 10 8 5 9 21 4 13 6 11 16 16 15 7 1 22 24 23 25...

Страница 37: ...93 11 Bracket electrical box mounting 01068139 Not shown Overload compressor 115 V 60 Hz 01027572 12 Compressor 115 V 60 Hz 01065259 13 Coil condenser 00195933 14 Tube clean and vent 00998765 Not show...

Страница 38: ...ystem Not shown Carbonless high capacity water filter system one per ice machine Horizon and Mae stroPlus series ice machines 01050442 Not shown Carbonless high capacity water filter cartridge primary...

Страница 39: ...MCD425A W R425A W MFD425A W P425A W Ice Machines 39...

Страница 40: ...PA 18040 USA Toll free 877 612 5086 1 610 252 7301 www follettice com SafeCLEAN SensorSAFE Maestro Plus Symphony Plus Quiet Night and Sani Sponge are trademarks of Follett LLC Follett and RIDE are re...

Отзывы: