6
400A/W 220 V 60 Hz/230 V/50 Hz Ice Machines
Plumbing
3/8" OD push-in water inlet
3/4" MPT drain
3/8" FPT condenser inlet (water-cooled condenser only)
3/8" MPT condenser drain (water-cooled condenser only)
Notes:
Slope to drain of 1/4" per foot (6mm per 30.4cm run) with a 1/2" minimum is recommended.
Water shut-off recommended within 10 feet (3m), drain to be hard piped and insulated.
Separate drains for ice machine and condenser. To prevent back fl ow, do NOT connect drains.
Follett recommends a Follett water fi lter system be installed in the ice machine inlet water line (standard
capacity #00130299, high capacity #00978957, carbonless high capacity #01050442).
Ambient
Air temp
38 C/100 F max.
10 C/50 F min. (best performance below 27 C/80 F)
Water temp
32 C/90 F max.
4 C/40 F min. (best performance below 21 C/70 F)
Water pressure
5 Bar/70 P.S.I max. (482kPa)
.69 Bar/89kPa/10 P.S.I. min.