25CI425A/W, 25HI425A, 50CI425A/W, 50HI425A
7
Installing countertop dispensers with bottom
exiting utilities
WARNING!
§
A sturdy work surface capable of supporting the
entire dispenser must be used .
§
The work surface must be large enough to
accommodate height of dispenser .
§
Failure to provide proper support may result in
personal injury .
1. Position dispenser with dispense chutes facing
upward on sturdy work surface
(Fig. 3) .
Fig. 3
5.00"
(12.7 cm)
min.
2. Move drain fitting from back of dispenser and
mount
(Fig. 4.1) .
3. Cut drain tube to length and attach to barbed
connection
(Fig. 4.2) .
4. Move inlet water fitting from back of dispenser
and mount
(Fig. 4.3) .
5. Cut water tubing to length and re-insert into
water fitting
.
6. Water-cooled only. Disconnect internal
condenser water inlet and outlet fittings .
7. Water-cooled only. Relocate water inlet and
outlet fittings and reconnect
(Fig. 4.4) . Note:
The water inlet is connected to the condenser;
the outlet line is connected to the water
regulating valve .
8. Remove the drain plug from the internal drain
line connection point and relocate to back of
dispenser and reconnect .
Fig. 4
Water cooled
only
TRIM DRAIN TUBE FOR
NEW DRAIN FITTING
LOCATION.
1
2
3
4
5
9. Raise the dispenser upright and position in
desired location .
10. Mark dispenser outline on counter and remove
dispenser .
11. Cut countertop utility opening and drill four
7/16" holes to anchor dispenser to counter
(Fig. 5) .
12. Apply a thick bead approximately 1/4" (7 mm)
diameter of NSF-listed silicone sealant (Dow
Corning* RTV-732 or equivalent) 1/4" (7 mm)
inside marked outline of dispenser .
13. Reposition dispenser on counter and secure to
counter with four 3/8"-16NC bolts .
14. Smooth excess sealant around outside of
dispenser and make utility connections
through countertop cutout .
CAUTION
§
Do not connect water-cooled condenser outlet line
to the dispenser drain line .
15. Turn on water supply and check for leaks .
16. Clean and sanitize dispenser and ice machine .
17. Turn power on and allow ice machine to
produce ice .
Fig. 5
2.50"
(6.36 cm)
12.50"
(31.8 cm)
14.00"
(35.6 cm)
4X
Ø.375"
(10 mm)
hole
21.00"
(53.3 cm)
20.00"
(50.8 cm)
1.56"
(4.0 cm)
0.50"
(13 mm)
16.00"
(40.7 cm)
1.56"
(4.0 cm)
Cutout
connections
through
bottom
16.50"
(41.9 cm)
7.00"
(17.8 cm)