25CI425A/W, 25HI425A, 50CI425A/W, 50HI425A
5
Electrical
§
115 V, 60 Hz, 1 phase, 11 .0A
§
Connect to a 15A dedicated circuit .
§
Furnished with 7 ft (2 m) power cord with a 90° NEMA hospital grade 5-15 plug .
Ambient
Air temp*
100 F/38 C Max .
50 F/10 C Min . (Best performance below 80 F (27 C)
Water temp
†
90 F/32 C Max .
45 F/7 C Min . (Best performance below 70 F (21 C)
Water pressure
70 P .S .I ./5Bar Max .
10 P .S .I ./0 .7 Bar Min .
* Ambient air temperature is measured at the air-cooled condenser coil inlet .
†
Ambient water temperature is measured in the ice machine float reservoir .
Plumbing
Connections 25/50CI425A
Rough-ins 25/50HI425A
Dispenser drain
3/4" MPT
Air-cooled 3/4" FPT
Water inlet
3/8" FPT
3/8" FPT
Condenser inlet
Water-cooled 3/8" FPT
N/A
Condenser outlet
Water-cooled 3/8" FPT
N/A
Note: Water shut-off recommended within 10 ft . (3m) of dispenser . Drain to be hard-piped and insulated . Maintain at
least 1/4" per foot (20mm per 1m) run of slope .
Ventilation clearances
Air-cooled
Water-cooled
Required for ventilation
3" (77 mm) each side
N/A
Suggested for service
12" (30 .5 cm) top,
6" (15 .3 cm ) left side
12" (30 .5 cm) top
Note: Do not block right side air intake or right side air exhaust .
Uncrated weight
§
25/50 CI425A/W (countertop): 215 lbs . (98 kg)
§
25/50 HI425A/W (wall mount): 230 lbs . (105 kg)