6
25CI425A/W, 25HI425A, 50CI425A/W, 50HI425A
Installation
Before you begin
§
All dispensers must be installed level in both directions to ensure proper operation .
§
Provide ventilation clearances mentioned above .
§
Countertop units provide the option of taking utilities out bottom or back of dispenser (on wall mount units and
countertop units with legs, utilities exit from back) .
§
Wall mount model utilities exit through back of dispenser only . .
§
Directions for each installation follow .
WARNING!
§
DO NOT LIFT UNIT AT THESE
POINTS . Panels will not support
weight of unit
§
Failure to follow warning may
result in equipment damage or
personal injury
Installing countertop dispensers with rear
exiting utilities (no legs)
1. Position dispenser in desired location .
2. Mark dispenser outline on counter and
remove dispenser .
3. Drill four 7/16" holes in counter to anchor
dispenser to counter
(Fig. 1) .
4. Apply a thick bead approximately 1/4" (7 mm)
diameter of NSF listed silicone sealant (Dow
Corning* RTV-732 or equivalent) 1/4" (7 mm)
inside marked outline of dispenser .
5. Reposition dispenser on counter and secure
to counter with four 3/8"-16NC bolts .
6. Smooth excess sealant around outside of
dispenser .
7. Make utility connections (Fig. 2) .
CAUTION!
§
Do not connect water-cooled condenser outlet line
to the dispenser drain line .
8. Turn on water supply and check for leaks .
9. Clean and sanitize dispenser and ice machine
before putting into service .
10. Turn power on and allow ice machine to
produce ice .
* Dow Corning is a register trademark of Dow Corning Corporation in the United
States and other countries
Fig. 1 Countertop anchoring locations
12.50"
(31.8 cm)
1.56"
(40 mm)
20" (50.8 cm)
.50"
(13 mm)
4X
Ø.375"
(10 mm)
hole
Fig. 2 Utility connections as viewed from top for
countertop back access
condenser inlet
3/8" FNPT
condenser outlet
3/8" FNPT
drain
3/4" MPT
potable water
3/8" FNPT
power