Normal operation – Stage 8
When the dwell time of 20 minutes has expired, the
TIME DELAY LED goes off . If 5 seconds of ice has been
dispensed and the
SLEEP CYCLE LED (Symphony Plus only) is off, the ice machine will go through the normal
start-up sequence when the bin level control signals the control board for ice .
5
2
1
Start
Run
Compressor
T.O.L.
MAINTENANCE
LOW WATER
TIME DELAY
SLEEP CYCLE
MAKING ICE
LOW BIN
POWER
SERVICE
HI AMPS
HI PRESSURE
DRAIN CLOG
CLEANER FULL
High
Pressure
Switch
R S
C
Gearmotor
Start
Relay
Start
Relay
N
L1
Fan
A B C D
Water Sensors
RESET
Fill
Valve
Drain
Valve
3
4
2
Bin T-Stat
Clean Switch
Drain Clog Sensor
P6
P21
P20
P19
P3
P22
P4
AUGER
WATER LEVELS
BIN P11
HI PRS
L1
R
S
C
RED
WHITE
WHITE
BLACK
BROWN
BLUE
RED
BLACK
YELLOW
Compressor
Electrical Box
COMPRESSOR
1 2 3 4 5 6 7 8
BLACK
N
P15
Ice Dispense Input
Capacitor
BLACK
YELLOW
OR
NO CONNECT
Quiet Night/Sleep cycle (Symphony Plus only)
The board monitors ice dispensing through a line voltage input to P15 . If the ice dispense has not be initiated for
more than 5 seconds during the 20 minute time delay, the
SLEEP CYCLE LED comes on . The machine will stay off
for 12 hours unless 5 seconds of dispensing is seen . After 12 hours, the
SLEEP CYCLE LED goes out and the ice
making will resume if the bin thermostat is closed . The sleep cycle dispense duration is adjustable using the DIP
switches on the control board .