93
5. Set the backsight information, and back to Rec menu.
NOTE
◆
If the inputted Pt# is the same as an existed one, the
instrument will display as shown left.
Press F3: [
NO
] to re-input;
Press F4: [
YES
] to overwrite;
Press F1: [
ADD
] to save, and the original one will not be
deleted.
◆
The max length of Pt# is 14 characters.
◆
The instrument height range: -9999.999~9999.999.
◆
The max length of code and user is 16 characters.
◆
Date and time are not allowed to change here.
◆
Weather options: Fine, Cloudy, Flurry, Rain, Snow.
◆
Wind options: Calm, Gentle, Light, Strong, Gust.
◆
The temperature range: -30 ~ 6
0℃.
◆
The pressure range: 500 ~ 1400 hPa
(
mbar
)
/ 375 ~ 1050 mmHg /14.8
~
41.3 inch Hg/
7.3~20.3 Psi.
◆
The ppm range: -499 ~ 499 ppm.
21.2 Collect Angle Data
1. Enter into record mode. The active JOB will
display.
2. Select “
2. Angle data
”, then aim at the target, the
angle will display in real time.
3. Press F4: [
REC
] to input the following items: point
number, target height and code, press F1: [
OK
] to
save data.
You could press F1: [
AUTO
] to perform this process
directly if PT#, code and tgt.H are unnecessary to
re-set.
Press F2:[
0SET
] to set horizontal angle as 0
4. Repeat step 3 to collimate and collect other points
angle data..
Pt# J2
Inst.H 0.000m
Code ROAD
N0: 0.000
E0: 0.000
Z0: 0.000
Overwrite ?
A D D
0
NO
0
Y E S
REC JOB-MY
1.Occ. data
2.Angle data
3.Collect Points
4.Note
5.View
6.JOB select
Meas PC 0.0
ppm 0
SD
VA 302.5432gon II
HA 0.0000gon P3
EDM OCC OFST R E C
REC/Angle Free 44000
VA 148.7080gon
HA 352.4228gon
Pt# PP01
Tgt.H 1.45ft
Code NO
AUTO 0SET R E C