2.  OPERATION 

 

2.1 Operating Procedures 

 
WARNING 
 

To  prevent  hand  injury,  keep  fingers  from  between  the  upper  and  lower  tooling 
and from between the lever and handle when closing hand tool. 

 
1.  Hold  the  hand  tool  so  that  the lever is  on the left. With  your index  finger,  push  and 

hold the terminal holder in its forward position. (See figure 2.) 

 
2.  Insert the disconnect (box) portion of the terminal, with "U" shaped barrels up, onto 

the holding pin and against the pin shoulder. While holding the terminal against the 
shoulder,  release  the  terminal  holder.  This  ensures  that  the  terminal  remains  in 
proper position while moving over the anvil. 

 

 

 
 
3.  While grasping the lever and the handle portion of the frame, insert a wire so that the 

end of the insulation is centered between the wire barrel and the insulation barrel of 
the terminal (see figure 3), then close the hand tool lever completely. This will crimp 
the terminal to the wire(s). 

 

Содержание HT95

Страница 1: ...HT95 Handpistol mini PV AWG 22 32 User s Guide...

Страница 2: ...tion 3 1 4Specifications 4 2 Operation 5 2 1Operating procedures 5 2 2Terminal inspection 6 3 Troubleshooting 8 4 Parts replacement procedure 9 4 1Anvil replacement 9 4 2Wire and insulation barrel cri...

Страница 3: ...arts which move with the lever The HT 95 is equipped with tooling for crimping two different ranges of wire sizes These are identified as A and B on a plate affixed to the hand tool frame The A side t...

Страница 4: ...or All Applications Single Wire 22 26 AWG or Two Wires 26 28 AWG 0 81 0 86 mm 0 032 0 034 in Single Wire 28 32 AWG or Two Wires 30 32 AWG 0 66 0 71 mm 0 026 0 028 in Insulation Barrel Crimp Height Dis...

Страница 5: ...ition See figure 2 2 Insert the disconnect box portion of the terminal with U shaped barrels up onto the holding pin and against the pin shoulder While holding the terminal against the shoulder releas...

Страница 6: ...d cause a defective crimp or damage to the tooling 2 2Terminal Inspection The crimped terminal should be inspected to ensure that the tooling is correctly aligned and that the wire was correctly inser...

Страница 7: ...portion of the terminal Check that the ends of the wire strands form an angle not exceeding approximately 45 Check that the wire barrel seam is even and tightly closed Next obtain a crimp height micro...

Страница 8: ...Tooling is broken or cracked Replace wire barrel crimper as described in Section 2 para graph 2 3 The sides of the terminals wire barrel are scored or scratched Wire barrel crimper is defective Replac...

Страница 9: ...osen the two 2 56 setscrews 12 in the anvil holder 4 and remove terminal holder assembly 10 2 Remove 4 40 cap screw 9 from the damaged anvil s 5 and 7 or 6 and 8 3 Remove damaged anvil 4 1 2 Installat...

Страница 10: ...Installation NOTE When replacing tooling always be sure that the part number on the part s being replaced is the same as the number of the part that was removed 1 Place the insulation crimper 2 onto t...

Страница 11: ...face the setscrew 12 in the anvil holder 4 1 Loosen the two 2 56 setscrews 12 in the anvil holder 4 Then remove the terminal holder assembly which includes the terminal holder 10 guide pins 15 0 ring...

Страница 12: ...er 11 and into the socket head setscrew Turn screw to the right 1 4 turn to unlock the adjusting collar 4 Insert the turned down end of the 3 32 inch Allen wrench supplied with hand tool or a pin appr...

Страница 13: ...lation barrel crimper 22 26 and 28 32 gauge wire 1 3 104959 1 Wire barrel crimper 22 26 and 28 32 gauge wire 1 4 102466 1 Anvil holder 1 5 104914 A Insulation barrel anvil 28 32 gauge wire 1 6 104914...

Страница 14: ...mmended spare parts for the hand tool are specified in bold type in the parts list for figure 6 6 2 Parts Ordering Information To obtain replacement parts contact F A Tooling NV Krijgsbaan 128 2640 Mo...

Страница 15: ...ate August 2007 Documentrev 3 Page 15 15 The technical data in this publication has been carefully checked and assembled No liability from inaccuracies or errors is assumed The right to change or impr...

Отзывы: