Table 1 Recommended diameters of welding cables

 

W elding current

 

30-100 A

 

100-200 A

 

200-300 A

 

15-30 m

 

25 mm

2

 

35 mm

2

 

50 mm

2

 

15-30 m

 

25 mm

2

 

50 mm

2

 

70 mm

2

 

30-60 m

 

35 mm

2

 

70 mm

2

 

90 mm

2

 

 

6. Operation 

 

 

POWER GENERATOR WITH WELDING MODULE

 

 

 

 

 
 
 

 
 
 

 
 
 

 

 

 

 

 
 

 

 

 DESCRIPTION OF THE CONTROL PANEL:

 

1. Selection of welding current

 

2. Selection of welding current range

 

3. Negative welding socket

 

 

4. Positive welding socket

 

 

 
 

 

CAUTION!!! Do not weld

 

 

and use the generator at the same time

 

 

 

To use the device as a power generator:

 

 

Set the switch (2) to "GEN"

 

Proceed as in "Starting

 

power generators" section

 

 

NOTE:  Do  not  switch  the  welding 
current  switches  
(1  and  1a)  during 
welding

 

 

NOTE:  During  the  welding,  voltage  is 
present on the power outlet sockets, but

 

its  voltage  is  low  and  unstable.  It  is  recommended  to 
unplug  the  devices  connected  to  the  socket  for  their 
safety.

 

 

NOTE:  The  welder  may  provide  the  maximum  welding 
current only for a few minutes, then it should  be left to 
cool  down  (see  the  table  on  the  control  panel)  - 
therefore if the work with high welding currents triggers 
the  thermal  switch  (welding  stops,  the  electrode  is 
'sticking')  let  the  power  generator  work  for  a  few 
minutes without load in order to cool it down.

 

 

 

Recommended diameters of welding cables:

 

 

To use the device as a welder:

 

-  Plug the grounding cable to the socket (3) 

-  Connect the grounding cable to the welded 

item,

 

-  Insert the plug of the cable with the electrode 

handle to the second positive socket (4).

 

 

-  Set the range of welding current with switch (1 ), 

(2),

 

-  Proceed as in section "Starting the power 

generator" without connected receivers.

 

Start welding.

 

 
 
 

examples of welding currents:

 

 

TAB.2

 

Welding current

 

Electrodes Acidic

 

Rutile

 

Cellulose

 

Basic

 

Semi-basic

 

1.5 mm

 

 

20-50A

 

 

 

20-30A

 

2.0 mm

 

 

40-65A

 

 

20-50A

 

30-60A

 

2.5 mm

 

60-110A

 

60-100A

 

50-90A

 

70-100A

 

50-80A

 

3.25 mm

 

90-150A

 

70-130A

 

70-130A

 

90-130A

 

60-100A

 

4.0 mm

 

140-210A120-160A 90-170A

 

110-170A100-140A

5.0 mm

 

200-
290A

 

190-
250A

 

140-210A 175-

220A

 

130-180A

 

18

 

Length 

Содержание FH 9000

Страница 1: ...FH9220W FH9540TR FH9540TRA FH9540TRE FH9540 BRIGGS FV10001CRA FV10001TE FV10001TRA FV10001TRE FV10300TWE FV10300WE FV11300TWE FV11001CRA FV11001TE FV11001TRA FV11001TRE FV13000CRA FV13000TE FV13000TR...

Страница 2: ...illegible or destroyed contact your Authorized Dealer of FOGO Sp z o o in order to replace them with new ones We strongly recommend carefully reading and understanding the safety rules included in ou...

Страница 3: ...generator it is essential to read these instructions The buyer of the power generator must ensure that this manual is always available for its operator and that every user reads the manual before sta...

Страница 4: ...Delivery unloading storage 11 5 Disposal 11 6 Operation 13 Starting 13 Stopping 17 7 Repair maintenance 19 List of maintenance operations 19 Maintenance methods 19 Faults 22 8 Maintenance 23 List of s...

Страница 5: ...t breaker electric starter and the battery The optional accessories include working hour meter grounding set transport kit a hose for the exhaust system welding wires units with a welding module autom...

Страница 6: ...peration The drive from the engine is transmitted through a tapered connection and threaded rod Alternator housing is made of light aluminium alloys Winding of the rotor and stator is insulated with a...

Страница 7: ...of the generator Cooling in these alternators is carried out by forced air circulation in slots outside the alternator 4 6 safe 8 9 10 11 12 MARKING OF THE POWER GENERATOR 2 1 13 14 DESCRIPTION OF THE...

Страница 8: ...uirements for explosion protection Do not fill the fuel tank while the engine is working RISK OF EXPLOSION Do not start the power generator in case of fuel spillage Restarting is permitted after remov...

Страница 9: ...rts Damage to the power cord increases the RISK OF ELECTRIC SHOCK If you work outside enclosed rooms use extension cords intended for use outdoors Using suitable extension cords reduces the RISK OF EL...

Страница 10: ...tor in conditions different than the nominal conditions Rated power is specified for specific operational conditions atmospheric pressure of 1 bar air temp of 20 C air humidity of 60 Power drop caused...

Страница 11: ...rator is up to 1 2 times higher than the rated power of the heaters Sodium power of the generator is up to 5 times higher than the rated power of the bulb UPS Power of the generator up to 1 7 times la...

Страница 12: ...ower generator against dust and corrosion clean the power generator from any dirt Detailed recommendations are presented in manuals provided by manufacturers of the engine alternator and other essenti...

Страница 13: ...ous waste includes used objects solids and liquids other than wastewater generated in households commercial facilities unsuitable for the place and time in which they have been generated and burdensom...

Страница 14: ...1 Oils shown in Table may be used if the average ambient temperature is within the indicated range For Briggs Stratton Vanguard SE SF SG SAE30 oils may be used Tab 2 Depending on the temperature for...

Страница 15: ...e of 12V and a capacity of at least 18Ah built in and non built in single cylinder generators 30Ah non built in two cylinder generators 35Ah built in two cylinder generators Connecting the battery to...

Страница 16: ...connection of the battery with faulty reversed polarity will automatically switch off the engine in Honda engines The green indicator in the switch indicates that the switch is turned off Remove the...

Страница 17: ...tch engages with the attaching basket located placed on the engine flywheel Vigorously pull the cord If the start up fails repeat until it is successful If the starter cord is pulled by engaging clutc...

Страница 18: ...il fuel mixture may overflow the piston and immobilize the engine In such cases remove the spark plug drain oil clean the combustion chamber with compressed air and change the oil VANGUARD CAUTION Whe...

Страница 19: ...mum welding current only for a few minutes then it should be left to cool down see the table on the control panel therefore if the work with high welding currents triggers the thermal switch welding s...

Страница 20: ...tic conditions especially at high humidity it is recommended to measure the insulation resistance of the alternator using a megohmmeter of 500 V The insulation resistance should be not less than 1 M I...

Страница 21: ...er with a new one Replacing the oil filter only the power generators with VANGUARD two cylinder engines Replace the oil filter every 100 operating hours or every season Before installing the new filte...

Страница 22: ...g agent and allow drying Cleaning the fuel sump MITSUBISHI engines Set the fuel valve at OFF position closed Remove the fuel sump together with the sealing O ring a fine mesh is installed above it to...

Страница 23: ...load 1 The capacitance of the capacitor is too high 2 Excessive engine speed 3 Damaged excitation system 1 Check and replace if necessary 2 Report to the Servicing Department 3 Report to the Servicing...

Страница 24: ...vities Engine speed control this activity must be performed by an authorized workshop service Checking the fuel system action performed in an authorised workshop MITSUBISHI FOGO DEFECTS National servi...

Страница 25: ...falling very quickly sometimes even after 2 3 weeks Do not use fuel older than 1 month Store a minimum amount of fuel required For a very long storage 1 Drain the fuel from the carburettor to a suitab...

Страница 26: ...n metal parts of the power generator It is also recommended for power generators equipped with other types of electrical protection Hose for exhaust system required when working indoors or on a vehicl...

Страница 27: ...10 Repair log book 26 REPAIR ORDER NO RECEIPT DATE DATE OF RETURN DESCRIPTION OF FAILURE REPAIR COMMENTS...

Страница 28: ...park plugs motor oil Only proper inspections ensure the correct functioning of the device Company selling the power generator Indication of working time counter Description of the fault If the power g...

Страница 29: ...park plugs motor oil Only proper inspections ensure the correct functioning of the device Company selling the power generator Indication of working time counter Description of the fault If the power g...

Страница 30: ...ion Type Engine No Power generator No Inspection Interval Counter indication Materials Part No Materials Part No Oil Oil Oil filter Oil filter Air filter Air filter Fuel filter Fuel filter Additional...

Страница 31: ......

Страница 32: ...which will be described in future versions of the manual by the services responsible for the change If you find any transcription errors or inconsistencies in the manual plese report them using the en...

Отзывы: