5. Disposal 

 

 

CAUTION!  Do  not  dispose  the 
generator  and  consumables  at  the 
end  of  their  operational  life  as 
household  waste!  All  waste  is  a 
potential  source  of  danger  and 
environmental pollution. 

 

It is categorically forbidden to cause 
environmental pollution by used materials or 
devices.  
All  materials  must  be  collected,  sorted, 
recycled  and  used  in  accordance  with  the  applicable 
national  regulations.  Information  on  the  appropriate 
disposal  of  used  devices  is  available  from  local 
authorities.

 

 

 

After  the  end  of  the  operational  life  of  the  power 
generator  or  any  of  its  parts,  dispose  them  in 
accordance  with  regulations.  The  following 
materials  must  be  provided  to  the  official  disposal 
sites,  as  they  may  be  hazardous  waste.  Hazardous 
waste includes used objects, solids and liquids other 
than  wastewater,  generated  in  households, 
commercial  facilities,  unsuitable  for  the  place  and 
time  in  which  they  have  been  generated  and 
burdensome for the environment.

 

It applies in particular to:

 

fluids (engine oil, coolant, etc.) 

- filters 
- starter batteries 
- a mixture of water and antifreeze agents 

any material soaked with operational fluids or 

diesel  oil 

materials  used  for  cleaning  (e.g. 

greasy,  fuel-soaked  or  contaminated  with 
chemicals cleaning cloth).

 

These  materials  must  be  provided  to 

organisations  authorised  to  purchase,  collect 
and  dispose  them.  Do  not  pollute  the 
environment,  or  store  the  materials  together 
with normal household waste.

 

If  the  generator  is  no  longer  used,  it  must  be 
delivered  to  the  organization  officially  involved 
in disposal of industrial machinery. 
The  used  power  generator  may  be  delivered  to 
the  manufacturer  of  power  generators  -  FOGO 
company.

 

 

 
 

 
 
 

 
 
 

 
 
 

 
 
 

 
 
 

 

12

 

Содержание FH 9000

Страница 1: ...FH9220W FH9540TR FH9540TRA FH9540TRE FH9540 BRIGGS FV10001CRA FV10001TE FV10001TRA FV10001TRE FV10300TWE FV10300WE FV11300TWE FV11001CRA FV11001TE FV11001TRA FV11001TRE FV13000CRA FV13000TE FV13000TR...

Страница 2: ...illegible or destroyed contact your Authorized Dealer of FOGO Sp z o o in order to replace them with new ones We strongly recommend carefully reading and understanding the safety rules included in ou...

Страница 3: ...generator it is essential to read these instructions The buyer of the power generator must ensure that this manual is always available for its operator and that every user reads the manual before sta...

Страница 4: ...Delivery unloading storage 11 5 Disposal 11 6 Operation 13 Starting 13 Stopping 17 7 Repair maintenance 19 List of maintenance operations 19 Maintenance methods 19 Faults 22 8 Maintenance 23 List of s...

Страница 5: ...t breaker electric starter and the battery The optional accessories include working hour meter grounding set transport kit a hose for the exhaust system welding wires units with a welding module autom...

Страница 6: ...peration The drive from the engine is transmitted through a tapered connection and threaded rod Alternator housing is made of light aluminium alloys Winding of the rotor and stator is insulated with a...

Страница 7: ...of the generator Cooling in these alternators is carried out by forced air circulation in slots outside the alternator 4 6 safe 8 9 10 11 12 MARKING OF THE POWER GENERATOR 2 1 13 14 DESCRIPTION OF THE...

Страница 8: ...uirements for explosion protection Do not fill the fuel tank while the engine is working RISK OF EXPLOSION Do not start the power generator in case of fuel spillage Restarting is permitted after remov...

Страница 9: ...rts Damage to the power cord increases the RISK OF ELECTRIC SHOCK If you work outside enclosed rooms use extension cords intended for use outdoors Using suitable extension cords reduces the RISK OF EL...

Страница 10: ...tor in conditions different than the nominal conditions Rated power is specified for specific operational conditions atmospheric pressure of 1 bar air temp of 20 C air humidity of 60 Power drop caused...

Страница 11: ...rator is up to 1 2 times higher than the rated power of the heaters Sodium power of the generator is up to 5 times higher than the rated power of the bulb UPS Power of the generator up to 1 7 times la...

Страница 12: ...ower generator against dust and corrosion clean the power generator from any dirt Detailed recommendations are presented in manuals provided by manufacturers of the engine alternator and other essenti...

Страница 13: ...ous waste includes used objects solids and liquids other than wastewater generated in households commercial facilities unsuitable for the place and time in which they have been generated and burdensom...

Страница 14: ...1 Oils shown in Table may be used if the average ambient temperature is within the indicated range For Briggs Stratton Vanguard SE SF SG SAE30 oils may be used Tab 2 Depending on the temperature for...

Страница 15: ...e of 12V and a capacity of at least 18Ah built in and non built in single cylinder generators 30Ah non built in two cylinder generators 35Ah built in two cylinder generators Connecting the battery to...

Страница 16: ...connection of the battery with faulty reversed polarity will automatically switch off the engine in Honda engines The green indicator in the switch indicates that the switch is turned off Remove the...

Страница 17: ...tch engages with the attaching basket located placed on the engine flywheel Vigorously pull the cord If the start up fails repeat until it is successful If the starter cord is pulled by engaging clutc...

Страница 18: ...il fuel mixture may overflow the piston and immobilize the engine In such cases remove the spark plug drain oil clean the combustion chamber with compressed air and change the oil VANGUARD CAUTION Whe...

Страница 19: ...mum welding current only for a few minutes then it should be left to cool down see the table on the control panel therefore if the work with high welding currents triggers the thermal switch welding s...

Страница 20: ...tic conditions especially at high humidity it is recommended to measure the insulation resistance of the alternator using a megohmmeter of 500 V The insulation resistance should be not less than 1 M I...

Страница 21: ...er with a new one Replacing the oil filter only the power generators with VANGUARD two cylinder engines Replace the oil filter every 100 operating hours or every season Before installing the new filte...

Страница 22: ...g agent and allow drying Cleaning the fuel sump MITSUBISHI engines Set the fuel valve at OFF position closed Remove the fuel sump together with the sealing O ring a fine mesh is installed above it to...

Страница 23: ...load 1 The capacitance of the capacitor is too high 2 Excessive engine speed 3 Damaged excitation system 1 Check and replace if necessary 2 Report to the Servicing Department 3 Report to the Servicing...

Страница 24: ...vities Engine speed control this activity must be performed by an authorized workshop service Checking the fuel system action performed in an authorised workshop MITSUBISHI FOGO DEFECTS National servi...

Страница 25: ...falling very quickly sometimes even after 2 3 weeks Do not use fuel older than 1 month Store a minimum amount of fuel required For a very long storage 1 Drain the fuel from the carburettor to a suitab...

Страница 26: ...n metal parts of the power generator It is also recommended for power generators equipped with other types of electrical protection Hose for exhaust system required when working indoors or on a vehicl...

Страница 27: ...10 Repair log book 26 REPAIR ORDER NO RECEIPT DATE DATE OF RETURN DESCRIPTION OF FAILURE REPAIR COMMENTS...

Страница 28: ...park plugs motor oil Only proper inspections ensure the correct functioning of the device Company selling the power generator Indication of working time counter Description of the fault If the power g...

Страница 29: ...park plugs motor oil Only proper inspections ensure the correct functioning of the device Company selling the power generator Indication of working time counter Description of the fault If the power g...

Страница 30: ...ion Type Engine No Power generator No Inspection Interval Counter indication Materials Part No Materials Part No Oil Oil Oil filter Oil filter Air filter Air filter Fuel filter Fuel filter Additional...

Страница 31: ......

Страница 32: ...which will be described in future versions of the manual by the services responsible for the change If you find any transcription errors or inconsistencies in the manual plese report them using the en...

Отзывы: