background image

3

© 

2021 Focal Point Fires Ltd.

2.0 INSTALLATION REQUIREMENTS

3.0 APPLIANCE DATA

Supply Voltage and rating power : 220-240V AC 50Hz, 1850W 

Heating Elements : 

2 x 925W

Location : 

Indoor use only

Fuse Rating : 

13 Amp

Lighting : 

LED's 

Supply plug/cord : BS1363/1.6 metres length

The appliance is supplied with a pre-wired three pin BS1363 plug (13Amp fuse rated) and 1.6 metres of electrical flex. It is therefore

necessary for a suitable electrical socket to be located within this distance of the appliance and be easily accessible. The stove may be

installed on a combustible or non-combustible floor, however the heater outlet is underneath the stove and certain types of floor cov-

ering may be affected by the heat produced by the stove. The ability of the floor covering to withstand the heat produced by the stove

should be ascertained before proceeding with the installation of the stove. If in doubt then the stove should be mounted on a non-com-

bustible hearth or plinth which extends for at least 150mm in front of the stove.This appliance should be positioned on a firm level sur-

face.  If the stove is to be sited in a fire surround then the suitability of the surround for use with electrical heaters should be estab-

lished with the fire surround manufacturer.If fitted into an open draught fireplace, it is advisable to block off the chimney to reduce the

risk of draught through the stove which may cause the safety cut out system in the fan heater to operate.

DO NOT

run the mains cable under carpets, rugs etc.

DO NOT

cover or obstruct the heater in any way. Overheating will result if it is acci-

dentally covered.

• Never immerse the product in water or any other liquids.

DO NOT

use the appliance outdoors.

• Before cleaning the appliance, ensure it is unplugged from the power and that it is com-

pletely cool.

DO NOT

clean the appliance with abrasive chemicals.

• Never use accessories that are not recommended or supplied by the manufacturer. It

could cause danger to the user or damage to the appliance.

DO NOT

insert or allow foreign objects to enter the inlet or outlet vents as this may

result in electric shock, fire or damage to the appliance.

DO NOT

install the fire using an extension cord.

• Unplug from the mains supply if the appliance is not to be used for long periods.

• This product is only suitable for well insulated spaces or occasional use.

1.0 IMPORTANT NOTES - CONTINUED

Model

ND-18

2ML

Item

Symbol

Value

Unit

Item

Unit

Heat output

Types of heat input, for electric storage local

space heaters only 

Nominal

heat output

P

nom

1.85

KW

Manual heat charge control with

integrated thermostat

N/A

Minimum heat

output
(indicative)

P

min

0.925

KW

Manual heat charge control with

room and/or outdoor temperature
feedback

N/A

Maximum
continuous heat

output

P

max, c

1.85

KW

Electronic heat charge control with
room and/or outdoor temperature

feedback

N/A

Auxiliary electricity consumption

Fan assisted heat output

N/A

At nominal
heat output

el

max

0.013 (fan

motor)

KW

Type of heat output/room temperature control

At minimum
heat output

el

min

0.013 (fan 
motor)

KW

Single stage heat output and no
room temperature control

No

In standby mode

el

SB

0.0

KW

Two or more manual stages no tem-
perature control

No

With mechanical thermostat room
temperature control

Yes

With electronic room temperature
control

No

Electronic room temperature con-
trol plus day timer

No

Electronic room temperature con-
trol plus week timer

No

Содержание ND-182ML

Страница 1: ...r written permission of Focal Point Fires Ltd 1 All instructions must be handed to the user for safekeeping Revision A 06 21 2021 Focal Point Fires Ltd Weybourne LED Electric Stove This product is onl...

Страница 2: ...y hot and cause burns Particular attention has to be given where children and vulnerable people are present If the supply cord is damaged it must be replaced by the manufacturer its service agent or s...

Страница 3: ...y covered Never immerse the product in water or any other liquids DO NOT use the appliance outdoors Before cleaning the appliance ensure it is unplugged from the power and that it is com pletely cool...

Страница 4: ...tivate heating function Increase or decrease flame brightness by clockwise or anti clockwise rotates the flame dimmer knob 2 Rotate thermostat knob 1 clockwise or anti clockwise to increase or decreas...

Страница 5: ...amps and fuses use only genuine manufacturers spare parts available from your supplier This product has one non self resetting overheat protection device thermal cut out which will activate if the air...

Страница 6: ...6 2021 Focal Point Fires Ltd All dimensions in mm 12 0 APPLIANCE DIMENSIONS 665 635 360...

Страница 7: ...not always possible to identify which components have been damaged Repaired or replaced products are covered only for the remainder of the original guarantee period and the guarantee period will not...

Отзывы: