VENTILATION AND ROOM SIZE (continued)
The room size should be a minimum of 40m
3
(e.g. 13’4” x 13’4” x 8’). to allow adequate circulation of air and
ensure the correct operation of the fire. This volume may include adjacent spaces but these spaces must not
be separated by a door. To calculate a room size in cubic metres (m
3
) divide the room volume in cubic feet
(ft
3
) by 35.3. This appliance is intended as a secondary source of heat only and should not be used in a room
without some form of background heating present.
OPERATING INSTRUCTIONS
The pilot is visible behind the left hand side of the burner.
The control knob is located on the lower right hand side of the outer
case. It is of a spherical design and is marked as shown in the dia-
gram to the right. Push in and turn the control knob to the SPARK
position, and hold there for a few seconds. Continue turning anti-
clockwise through the spark click to the PILOT light position, ensur-
ing the pilot has lit. If not, return the knob clockwise, and repeat.
When the pilot lights after the spark, keep the knob depressed for
approximately ten seconds. Now release the knob and the pilot
should stay alight. If the pilot is extinguished during use, wait three
minutes before repeating the ignition procedure.
To achieve the HIGH setting, push the control knob in slightly and
continue turning anti-clockwise to the high position. The main burn-
er should light after a few seconds. To decrease the setting to LOW,
turn the control knob clockwise to the low setting.
To turn to the PILOT position from the HIGH or LOW positions,
press the control knob in, and return to the pilot position and release.
To turn the fire OFF, keep the knob pressed in, return to the off posi-
tion and release.
COMBUSTION MONITORING SYSTEM
This fire is fitted with a combustion monitoring safety device (ODS). If the appliance shuts down during use for
no apparent reason then several reasons may be suspected. If a door or window has been opened creating a
draught, then pilot disturbance could be the problem and removal of the draught should resolve this. The appli-
ance can then be re-lit in accordance with the previous section.
If pilot disturbance is not the cause, then the ODS safety system may be in operation. Switch the appliance OFF,
call in your installer to check the appliance and ventilation. Remedial work must be carried out as required. DO
NOT allow the appliance to be used until the appliance and installation is passed as safe. If the pilot continues
to be extinguished, you must call your installer to check the operation of the complete appliance.
CLEANING
Before carrying out any of the following operations, ensure that the appliance is OFF and completely cold.
INNER GLASS PANEL - This can be cleaned with proprietary window-glass cleaner, or propriety ceramic hob
cleaner. Test on a small area first.
GRANITE SURFACES : A soft lint-free duster should be used for day to day cleaning. Other marks , such as fin-
ger-prints may be removed from the granite frame by using proprietary window-glass cleaner, or NET-TEX hard
surface cleaner.
LIMESTONE SURFACES : Limestone is porous and can be susceptible to marking in use. It may be cleaned with
a small amount of warm soapy water. Any stubborn stains may be removed with a diluted liquid domestic bleach
and water solution. Superficial scratches or stubborn surface stains can be smoothed out using a fine grade wet
& dry sandpaper. Joints may be grouted using a matching tile grout.
PAINTED AREAS - These can be cleaned using a dry lint-free cloth.
SERVICING
The appliance should be checked on an annual basis to ensure it is working safely. The frequency of service will
depend on usage, but MUST be carried out at least once annually. Servicing must be carried out by a compe-
tent person, such as a CORGI registered installer. The Installation instructions carry full servicing details for the
use of the installer.
LIST OF SPARE PARTS
PART NO.
ITEM
F960017
Inner glass door assembly (Pinoir, Memoirs and Reflection models)
F960006
Inner glass door assembly (Saturn models)
F730023
Pilot assembly (Natural gas models)
F730075
Pilot assembly (LPG models)
F730076
Gas valve
Please enquire
Burner unit
4.0
5.0
3.0
‘OFF’ position
‘SPARK’ position
‘LOW’ position
‘HIGH’ position
7.0
6.0
8.0
F860595
As our policy is one of continuous improvement and development , we hope therefore you will understand we must retain the right to amend
details and/or specifications without prior notice.