FIXING THE APPLIANCE

Remove any protective film coatings from the finished/decorative surfaces
of the appliance. After having selected the final mounting position of the
appliance, taking into account the requirements as specified in sections 3
and 4 of these instructions, the integrity of the wall, and the feasibility of
the proposed supply pipe routing, the firebox of the appliance may be
secured to the wall.  
To ensure customer safety, be sure to design the installation so that the
strength of both the wall and any wall fixings used are sufficient. Focal Point
Fires plc. assumes absolutely no responsibility for injuries and damages that may occur due to improper installation or
handling. The appliance should not be installed until all wet plastering and/or dry wall sanding and wall painting has
been completed and the wall is fully cured.  Do not block the ventilation holes of the appliance. The wall onto which
the appliance is installed must be flat. Install only on a vertical surface.  Avoid sloped surfaces. Installation onto any-
thing other than a vertical wall may result in fire, damage or injury.

If the appliance is to be mounted on the inner leaf of a conventional cavity brick wall, or a solid wall, then the wall
plugs and fixing screws provided may be used. Depending on the condition of the wall it may be necessary to use
additional fixings. In this situation, any additional fixings and wallplugs should be of the same size and type as the ones
provided. At the appropriate stage of the installation, drill four holes using only a
8.0mm masonry bit to a depth of 43mm. 

Insert the wallplugs provided ensuring they are flush to the wall. If the appliance is to
be mounted on a dry lined wall or a timber framed construction wall then efforts
should be made to fix in at least two positions vertically, into one of the wooden studs,
or supporting wooden members of the wall using two of the fixing screws provided.
If this is not achievable then the wall should be strengthened
using appropriate building materials. 

If there is no alternative than to rely on 

some plasterboard fixings

then special cavity screw fixings or hollow wall anchors will be
required which are not supplied with this product. These should

be constructed from
metal and not plastic
and of the design indi-
cated to the right. For
further guidance for
wall fixing in timber
framed buildings,
refer to the current

edition of IGE/UP/7. 

Using the fitting template provided, mark the fixing positions on the wall. 
Pinoir, Memoir and Reflection models : Mark the positions shown as ‘L40 fixing points’. 
Saturn models : Mark the Positions shown as ‘Saturn’ fixing points.

If a concealed gas connection is to be made ensure the gas supply pipe is in it’s final position and can enter the appli-
ance in the correct position when the appliance is hung on the wall. Drill the wall as appropriate for the type of wall
as previously described in this section, and insert the chosen type of wall fixings. Insert the wall fixing screws into the
top wall plugs, taking care to leave the screws protruding approximately 5mm from the wall. Now hang the appliance
onto these screws through the two keyhole shaped holes in the upper brackets on the back panel of the appliance. 

Insert the lower fixing screws into the lower wall plugs through the corresponding fixing holes in the lower part of the
back panel. Do not tighten fully.  Before tightening the wall mounting screws fully, at this stage it is recommended to
check the horizontal alignment of the appliance with a spirit level, as small adjustments can still be made if necessary.
When this has been checked, tighten all four fixing screws fully.  To access the upper fixing screws insert a screwdriv-
er through the round access holes in the heat deflectors directly above the catalysts.  
Pinoir/Memoir models: To access these holes the front heatshield of the outlet grille will need to be released. This is
achieved removal of the two retaining screws, one on either side, located at the top front corners of the firebox. 

CHECKING THE BURNER

There are no imitation fuel bed components to install. The appliance features a ribbon burner which is designed to
produce a continuous band of flame over it’s length. 
The burner should be visually inspected to ensure it is free from any foreign matter. 
If it is necessary to clean or dust off the burner then the glass door should be removed by removal of the four retain-
ing screws. Re-fit the glass door after cleaning or inspection, ensuring the correct orientation and a good seal.

5

7.0

7.1

Plasterboard alone is not considered
to be a structural material.
It is not recommended to rely on
plasterboard fixings alone to support
the weight of the appliance.

WARNING

©

2008 Focal Point Fires plc.

The wall where the appliance is to
be installed must be capable of long-
term support of the total load of the
appliance. Measures should also be
taken to ensure sufficient strength to
withstand the force of earthquakes,
vibration and other external forces.

WARNING

Содержание MEMOIRS

Страница 1: ...safekeeping Revision B 10 08 Country s of destination GB IE PINOIR MEMOIRS REFLECTION SATURN WALL MOUNTED HIGH EFFICIENCY GAS FIRE Focal Point Fires plc Christchurch Dorset BH23 2BT Tel 01202 499330...

Страница 2: ...he text images and layout of this booklet is owned by Focal Point Fires plc You are not per mitted to copy or adapt any of the content without the prior written permission of Focal Point Fires plc The...

Страница 3: ...moke candle smoke etc exist may cause the walls to become discoloured This appliance is intended as a secondary source of heat only and should not be used in a room without some form of background hea...

Страница 4: ...igned to be wall hung Do not recess any part of the appliance into the wall This appliance may be installed in any room in the home except bathrooms or bedrooms Installation in living rooms is common...

Страница 5: ...appliance are able to withstand prolonged exposure to moderate heat and moisture before proceeding with their installation The back of the appliance may be installed directly onto a combustible wall...

Страница 6: ...s supply pipework to enter the appliance firebox These entry points are knock out type holes Select the most appropriate entry point and knock out the relevant hole The positions of these holes are sh...

Страница 7: ...on of IGE UP 7 Using the fitting template provided mark the fixing positions on the wall Pinoir Memoir and Reflection models Mark the positions shown as L40 fixing points Saturn models Mark the Positi...

Страница 8: ...his If under any circumstances the piezo electric spark fails the pilot cannot be lit man ually SETTING PRESSURE The pressure test point is located on the left hand side of the appliance on the main b...

Страница 9: ...he appliance and the need for regular servicing Frequency of service depends on usage but MUST be carried out at least once annually Advise that cleaning of the fire maybe achieved when the fire is co...

Страница 10: ...sary is to ensure the spark gap is correct See specifications for gas setting NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY ALIGHT If the pilot will not stay lit there is a problem with...

Страница 11: ...ay lit there is a problem with dirt the gas supply or the thermocouple needs replacement Modifications are dangerous and can have a serious unseen effect on safety NEVER MODIFY OR BEND THE THERMOCOUPL...

Страница 12: ...this appliance considers all surfaces as working surfaces with the exception of the control knob and control panel Combustible items such as flooring and furniture and soft wall coverings such as blo...

Страница 13: ...ished that any mirrors or picture frames etc to be positioned on the wall above the appli ance are able to withstand prolonged exposure to moderate heat and moisture before proceeding with their insta...

Страница 14: ...ous section If pilot disturbance is not the cause then the ODS safety system may be in operation Switch the appliance OFF call in your installer to check the appliance and ventilation Remedial work mu...

Отзывы: