30
Installation and Operation Manual
10
Make Sure Everything Is Working Right
Hydraulic Supply (Refer to Sections 4 & 7)
❑
Hydraulic pump is properly mounted to the PTO.
❑
Hydraulic oil lines are properly routed and tight.
❑
Filter(s) are installed and tight.
❑
Oil reservoir is filled with correct fluid.
❑
Oil primed to hydraulic pump.
❑
Adequate oil cooler reservoir capacity.
Electrical (Refer to Section 9)
❑
Tank level sensor is connected and connections are sealed from moisture.
❑
Digital Display Control Module connections are correct and tight.
❑
Cable connections at valve drive box are correct and tight.
❑
Flowmeter cable(s) are properly connected to the Digital Display Control Module as required.
❑
All cables are secured and protected with loom from damage during operation.
❑
RFI/EMI beads are installed; control and flowmeter cables are properly folded and secured; radio antennas,
power lines, and equipment are away from control cables and flowmeter cables.
❑
All components, Digital Display Control Module, Flowmeter Tee, and Pump Base are properly grounded
using flat ground straps.
❑
Adequate current is available; 5 AMP minimum.
❑
Circuit breaker on the valve driver box is in the ON position.
Liquid (Refer to Section 8
)
❑
Water flowmeter is mounted with flow arrow in the correct direction for water flow.
❑
Check valves are properly mounted in water and foam concentrate lines.
❑
Strainer is properly mounted for direction of concentrate flow in the foam tank and pump line.
❑
Foam tank to foam pump valve is in place and open.
❑
Injector fitting lines are properly sized and connections are tight.
❑
CAL/INJECT valve is properly mounted and oriented for direction of concentrate flow.
❑
Foam concentrate is gravity fed to foam pump.
❑
Foam concentrate flowmeter is properly installed with the flow arrow in the correct direction.
Foam Pump (Refer to Section 6)
❑
Foam pump inlet and discharge ports are properly sized and installed.