Foamit APW20HT Скачать руководство пользователя страница 9

Model: APW20HT

V20190916 • Page 9

1 .

  Lift the sink up from the base. 

2 .

  Fill the base with the aqueous 

based solution. Important! Do 

not fill higher than the maximum 

fill line. The equipment has a 

maximum capacity of 20 gallons 

(75.7 liters).

3 .

  After the base is filled, place  

the control box assembly and 

sink back onto the base,  

re-connect the supply hose if 

necessary, and open the lid. 

Important!

 Always ensure the 

heater is submerged in the 

solution during operation of 

the equipment. Do not run the 

equipment if the heater is not 

submerged in the solution. This 

will damage the unit.

4 .

  Press the heater on/off switch 

and turn the heater On. Note: It 

takes about 1 1/2 hours to heat 

very cold solution to 105° F 

(40.5° C).

5 .

  Press the pump on/off switch 

and turn the pump On.

6 .

 

Place the parts in the sink. 

Important

! Do not overfill  

the sink. Maximum weight of  

the part(s) should not exceed 

400 lbs.

4

 

Use

Important!

 Only aqueous (water) based solutions shall be used with this equipment. It is beyond the scope of this 

manual to describe every aqueous based solutions available. It is the user’s responsibility to ensure the use of 

proper solutions with this equipment. 
Chemical solutions must be formulated for this type of application and compatible with unit materials and pump 

seals. Always read, and follow, all chemical safety precautions and handling instructions provided by the solution 

manufacturer and the Safety Data Sheet (SDS) associated with the solution being used before using the equipment.  

Never use any amount of non-aqueous solvent with this equipment.

Follow these steps to use the equipment:

LOW FLUID

 

AT TEMP

 

R

I

N

S

E

B R U S H

Fire and explosion hazard. 

No solvents, mineral spirits 

or other flammable products.

Use only water based cleaners.

Drain parts of flammable contents.

!

Read and follow user manual and 

warning to avoid rish and serious injury 

or death. 
Know hazards of your chemical. Read 

and follow safety data sheets (SDSs).

!

ON

OFF

ON

OFF

LOW FLUID

 

AT TEMP

 

R

I

N

S

E

B R U S H

Fire and explosion hazard. 

No solvents, mineral spirits 

or other flammable products.

Use only water based cleaners.

Drain parts of flammable contents.

!

Read and follow user manual and 

warning to avoid rish and serious injury 

or death. 
Know hazards of your chemical. Read 

and follow safety data sheets (SDSs).

!

ON

OFF

ON

OFF

Maximum 

fill level

The AT TEMP 

light will come on 

when the solution 

temperature 

reaches 105° F 

(40.5° C)

The low fluid light 

will flash when 

the solution level 

is below the float 

switch and the 

control box will 

turn off.

3

4

2

5

Содержание APW20HT

Страница 1: ...F ON OFF Heated Aqueous Parts Washer User Manual APW20HT READ ALL INSTRUCTIONS BEFORE USING OR SERVICING THIS EQUIPMENT KEEP THIS MANUAL IN A LOCATION THAT IS READILY AVAILABLE TO USERS AND SERVICE TE...

Страница 2: ...2 Model APW20HT Contents 1 Safety 3 Safety Labels 4 2 Product Overview 5 3 Installation 6 System Requirements 6 System Specifications 6 Assembling the Equipment 7 4 Use 9 5 Cleaning Maintenance 11 6 T...

Страница 3: ...ng Read and follow all chemical safety precautions and handling instructions provided by the solution manufacturer and the Safety Data Sheet SDS associated with the solution being used before using th...

Страница 4: ...this unit with parts not listed in this manual may cause the unit to operate improperly Do not use unauthorized parts when servicing the unit Running the heater element without being completely submer...

Страница 5: ...cal Plug 13 Pump On Off Switch 14 Heater On Off Switch 15 Low Level Light 16 AT TEMP Light 17 Supply Hose Quick Connect 18 Sink Hose Quick Connect 19 Pump 20 Low Fluid Switch 21 Heating Element Contro...

Страница 6: ...mical compatibility consult the manufacturer or SDS for your product or contact our customer service department Power type Electricity Chemical pickup type Draws from pre mixed solution Number of prod...

Страница 7: ...quick connect hose from the sink to the supply hose quick connect from the pump 6 Place the sink on top of the base The equipment is shipped in two boxes check that all the parts are included and unda...

Страница 8: ...s ON OFF ON OFF LOW FLUID AT TEMP Fire and explosion hazard No solvents mineral spirits or other flammable products Use only water based cleaners Drain parts of flammable contents 7 Open the lid 8 Pla...

Страница 9: ...bility to ensure the use of proper solutions with this equipment Chemical solutions must be formulated for this type of application and compatible with unit materials and pump seals Always read and fo...

Страница 10: ...multaneously 9 Remove the parts and repeat steps 6 8 with additional parts 10 Monitor the drain grate and filter bag for accumulated solid waste Monitor the solution quality Conduct maintenance if nee...

Страница 11: ...the edge of the sink and into a suitable container 2 Move the rinse brush handle to the rinse position and drain as much solution as possible 3 To completely drain the solution a Lift up on the right...

Страница 12: ...y j Place the sink on the base k Reconnect the air supply 6 Troubleshooting Issue Solution Solution doesn t flow through the Flexible Rinse Line or Flow Thru Brush Check the hoses between the Sink and...

Страница 13: ...r chemical Read and follow safety data sheets SDSs ON OFF ON OFF LOW FLUID AT TEMP Electrical shock hazard Unplug unit before servicing 7 Parts Item number Description PW LID A Includes Lid Spring Hin...

Страница 14: ......

Отзывы: