Figure 8: EMGZ482R.Modbus electrical connection
RTM_X42_Modbus_BA_Manual.ai
EMGZ482R.Modbus pin assignment
Pin(s) Description
1 24
VDC+
2 24
VDC-
3 PE
10, 11
24 VDC output
12
GND for 24 VDC
13
Digital input for production length
14
Analog input for force sensor core
16, 26
Relay 1/1 – 1/2
Configurable relay outputs 1 to 4:
Tension value limits channel 1, 2; tension value
limits collective alarm, limit pre alarm collective
alarm, radio connection, battery state of charge,
core tension value
17, 27
Relay 2/1 – 2/2
18, 28
Relay 3/1 – 3/2
19, 29
Relay 4/1 – 4/2
Table 2: EMGZ482R.Modbus pin assignment
The RTM X42 system has pre-configured relay outputs. The respective alarm output is
activated if the assigned function condition occurs.