RTM X42.Modbus Installation Manual and Operating Instructions
09.12.2019
33
ANYBUS Gateway AB9001 input register
Offset Type Length
Name
Description
32
INT16
1
Channel 32
Raw date in digits (ADC value)
5898 digits= nominal force
= 5.4mV analog DMS input
33 INT16
1 Channel
33
34 INT16
1 Channel
34
35 INT16
1 Channel
35
36 INT16
1 Channel
36
37 INT16
1 Channel
37
38 INT16
1 Channel
38
39 INT16
1 Channel
39
40 INT16
1 Channel
40
41 INT16
1 Channel
41
42 INT16
1 Channel
42
43
UINT32
2
Counter (time)
Time counter 10 ms after restart
45 UINT32 2 Counter
(pulse)
(production length)
Pulse counter after restart
47 UINT16 1 Analog
input
(core)
Raw date in digits (ADC value)
0 to 8192 digits= 0 to 10V
48
INT16
1
Battery pack
Raw date in digits (ADC value)
2530 digits = 100%
2380 digits = 80%
2200 digits = 60%
1860 digits = 40%
1420 digits = 20%
< -2000 digits= 24V excitation
49 UINT16 1 STATUS
BIT0=
relay 1, status 1 = set
BIT1= relay 2, status 1 = set
BIT2= relay 3, status 1 = set
BIT3= relay 4, status 1 = set
50
UINT16
1
Installed channels Number of valid channels
Table 9: Gateway input register