10
Error Causes and Troubleshooting
Troubleshooting
Message
Cause
Remedy
“Radio link lost”
Radio connection to the
EMGZ482T is
interrupted.
Metal objects interfere
with the transmission
path
Check battery in the EMGZ482T
(battery empty or not
inserted?).
Remove antennas from the
interference range.
“Channel X >min. limit”
“Core >min. limit”
The faulty channel is
active, however not
connected to a force
sensor.
Connect force sensor to the
respective connector of the
EMGZ482T or EMGZ484T.
“Modbus Error”
MODBUS connection
faulty.
Contact FMS Service Center.
Very small force
amplitudes to PLC.
Calibrated incorrectly
Repeat calibration
Changed parameters
cannot be saved
Change procedures was
not completed correctly
The change must be confirmed
with “Save parameters” and
“OK” after parameter inputs