RTM x42.IO.Modbus Installation Manual and Operating Instructions
03.02.2020
21
System Parameters
Values
German, English
Default English
Inv.Sign
Inverts the signal of all force sensors
Unit [-]
Values
Yes, No
Default No
RL CTRL
Restrictions for access to configuration.
RTM X42 – full configuration via operating panel
PC – full configuration only via web browser. Only limited configuration
via operating panel ( parameters: LANspeed, Gateway, IP Adres, Supnet
RL CTRL)
Unit [-]
Values
RTM X42, PC
Default RTM
X42
FiltMode Off:
-
Deactivated
N-Linear:
-
Non-linear filter of second order
Low pass
-
Filter of first order
Unit [-]
Values
Off; N-Linear; Low pass
Default Off
Filt_Out
Frequency for N-Linear and Low pass filter
Unit Hz
Min
0.1
Max
100
Default 10
LANSpeed
Data rate of LAN connection
Unit BPS
Min
10
Max
100
Default 100
IP Addr.
IP address (static) of the EMGZ482R.Modbus receiver module. Address