FMS-cradleGUARD Operating Manual and Installation Instructions
24.07.2019
9
Figure 3: FMS-cradleGUARD.T Terminal Designation and Connection
FMS_cradleGUARD_BA_Manual.ai
Designation of sensors
You can modify the below stated names (Pintle,…) of the sensors via
the web browser.
FMS-cradleGUARD.R
Item Description
1 to 3
Sensor 1 – PINTLE LEFT (pintle lock left)
Terminal 1: +12 VDC power supply (can be measured using an
oscilloscope only)
Terminal 2: Signal / switch
Terminal 3: GND / reference
4 to 6
Sensor 2 – PINTLE RIGHT (pintle lock right)
Terminal 4: +12 VDC power supply (can be measured using an
oscilloscope only)
Terminal 5: Signal / switch
Terminal 6: GND / reference
7 to 9
Sensor 3 – WIRE BREAK
Terminal 7: +12 VDC power supply (can be measured using an
oscilloscope only)
Terminal 8: Signal / switch
Terminal 9: GND / reference