FMS-cradleGUARD Operating Manual and Installation Instructions
24.07.2019
20
Figure 12: Relay Settings
FMS_cradleGUARD_BA_Manual.ai
You can define individual trigger conditions for the 4 relay outputs in the receiver module.
Web Interface – Relay Settings
Function Description
Disabled Without
function
Pintle left
If 2 pintles exist on the cradle, they can be differentiated
here.
Pintle right
Wire Break
Detection of a wire break using the respective sensor.
The response time until relay triggering can be up to 8.4
seconds.
Tilt
Is mainly used for tubular type stranders and to detect
cradle swinging.
Radio lost
The quality of the radio connection of the individual
transmission modules is checked continuously. A relay can
be switched in the case of a poor connection.
Battery low
Is activated if the charging status of the battery drops below
20%. A runtime of a few days is left prior to battery
replacement. This alarm does not affect the Master alarm.
Master alarm
Is activated as soon as any fault state occurs, regardless of
the configuration of other relay outputs.
Table 10: Relay Settings