FMS-cradleGUARD Operating Manual and Installation Instructions
24.07.2019
16
5.2
Display
If configured sensors or switches are activated this will be shown on the display.
Figure 7: Display during start-up and without error
FMS_cradleGUARD_BA_Manual.ai
Figure 8: various error messages FMS_cradleGUARD_BA_Manual.ai
Line 1 – individual ID of the transmission module FMS-cradleGUARD.T
Line 2 – specific error message
If multiple errors occur at the same time, the display will switch and indicate all errors in
sequence.
5.3
Configuration via Web Interface
The system can be integrated in an Ethernet network and configured via a browser (e.g.,
Internet Explorer 8 or higher). The FMS-cradleGUARD.R receiver module has a static IP
address, which can be set via the control panel. The IP address is not automatically obtained
via DHCP.
Alternatively, the system can be configured using a desktop or laptop computer via a peer-to-
peer connection. However, the computer must be disconnected from the network and have a
static IP address for this purpose. The static IP address must not be identical with the IP
address of the receiver module.
Follow the instructions as soon as the connection is established:
-
Open a browser (e.g., Microsoft Internet Explorer, Mozilla Firefox, etc.)
-
The default address of the receiver module is 192.168.000.090. If you have not change it,
enter this IP address into the input field (e.g., http://192.168.000.090) and confirm with
“Enter.”
User interface language
The user interface of the browser is only available in English