background image

 

FMS-cradleGUARD Operating Manual and Installation Instructions

 

 

24.07.2019

 

 

14 

 
 

FMS-cradleGUARD.R 

Item Description 

4 Navigation 

keys 

 

Left – Scroll parameter list to the left  
Right – Scroll parameter list to the right  
Up – Increase parameter value 
Down – Decrease parameter value 

5 Enter 

key 

Select parameter, confirmation 

6; 7 

Menu key, status LED 
By pressing and holding the menu key (> 3 seconds), you can enter the 

configuration menu of the system parameters. The status LED lights up 
until you exit the menu by pressing and holding the menu key again (> 3 
seconds). 

Cover with 4 fastening screws 

PG gland for cable feed-through (24 VDC) 

10 

Lower fastening lug 

Table 5: FMS-cradleGUARD.R 

5.1

 

Configuration on the Device 

Only a basic parameter can be set on the device. The configuration itself has to be done via 
the web interface. 
By pressing and holding the menu key (> 3 seconds), you can enter the menu of the system 
parameters. 
-

 

By pressing on the “left” and “right” keys, you can navigate through the parameter list. 

-

 

By pressing the enter key, you select the system parameter to be changed. 

-

 

Now, the name of the parameter to be changes is flashing 

-

 

By pressing the “up” and “down” keys, the parameter value can be changed. 

-

 

By pressing the enter key, you confirm your input and the changed value is saved. 

-

 

Press and hold the menu key again (>3 seconds) to exit the menu. If nothing is entered on 
the device, the menu is automatically exited after 60 seconds.   

 
 

 
 
 
 

 
 
 

Содержание FMS-cradleGUARD

Страница 1: ...ission from Cradle to Control Station Document Version 2 10 Published Author 07 2019 NS Diese Bedienungsanleitung ist auch in Deutsch erh ltlich Bitte nehmen Sie mit der n chstgelegenen FMS Niederlass...

Страница 2: ...2 Preparation 7 4 3 Installation of the FMS cradleGUARD T Transmission Module 7 4 4 Electrical Connection of the FMS cradleGUARD T Transmission Module 8 4 4 1 Connection of Sensors and Switches 10 4 5...

Страница 3: ...only be performed by expert personnel 2 1 Presentation of Safety Information 2 1 1 Danger that Could Result in Minor or Moderate Injuries Danger warning caution Type of danger and its source Possible...

Страница 4: ...lation information on the following pages must be followed The local installation regulations ensure the safety of electrical systems They are not considered in these operating instructions However th...

Страница 5: ...tional safety The receiver module FMS cradleGUARD R outside of the machine receives the signals of the individual transmission modules and indicates their status in plain text on the display The integ...

Страница 6: ...to 3 per FMS cradleGUARD T transmission module or per cradle not shown 24 VDC connection for FMS cradleGUARD R receiver module Ethernet cable etc Table 1 Main Components 3 4 Scope of Supply Scope of s...

Страница 7: ...e following conditions must be met to ensure proper function The components may not be subjected to loads outside of the specified values during installation and operation later The fastening points f...

Страница 8: ...possible In the case of small machines and light weight cradles make sure that the additional weight of the transmission module may have to be compensated to avoid any imbalance We recommend a centere...

Страница 9: ...ription 1 to 3 Sensor 1 PINTLE LEFT pintle lock left Terminal 1 12 VDC power supply can be measured using an oscilloscope only Terminal 2 Signal switch Terminal 3 GND reference 4 to 6 Sensor 2 PINTLE...

Страница 10: ...l assignment do not change B Dip switch for setting the ID do not change Table 3 Terminal Block for FMS cradleGUARD T Sensors Do not change the Dip switches Changing the Dip switches will result in th...

Страница 11: ...FMS cradleGUARD Operating Manual and Installation Instructions 24 07 2019 11 Figure 4 Sensors and Switches FMS_cradleGUARD_BA_Manual ai...

Страница 12: ...ad screws We recommend a 3 x 0 5 mm2 cable for the power supply The cable must be routed separately from the power cable Figure 5 Electrical Connection of the FMS cradleGUARD R FMS_cradleGUARD_BA_Manu...

Страница 13: ...ting Manual and Installation Instructions 24 07 2019 13 5 Display and Operation Figure 6 Control Panel and Display FMS_cradleGUARD_BA_Manual ai FMS cradleGUARD R Item Description 1 Antenna 2 Upper fas...

Страница 14: ...rough 24 VDC 10 Lower fastening lug Table 5 FMS cradleGUARD R 5 1 Configuration on the Device Only a basic parameter can be set on the device The configuration itself has to be done via the web interf...

Страница 15: ...5 255 255 0 Gateway The address of the gateway must be entered in 4 blocks Min 0 Max 255 Default value 255 255 255 0 Language Display language on the device display Min German Max English Default valu...

Страница 16: ...her The FMS cradleGUARD R receiver module has a static IP address which can be set via the control panel The IP address is not automatically obtained via DHCP Alternatively the system can be configure...

Страница 17: ...ting Manual and Installation Instructions 24 07 2019 17 Figure 9 Home FMS_cradleGUARD_BA_Manual ai Web Interface Home Item Description 1 Page navigation Table 7 Home Figure 10 Current Reading FMS_crad...

Страница 18: ...m factor of the browser window the tables can also be arranged among each other 5 Column ID IDentification Every FMS cradleGUARD T transmission module has its own ID number for easy assignment The ID...

Страница 19: ...or the 3 sensors that can be connected per transmission module 3 different connection possibilities can be selected Deactivated No sensor is connected The sensor status is not shown on the display Act...

Страница 20: ...ive sensor The response time until relay triggering can be up to 8 4 seconds Tilt Is mainly used for tubular type stranders and to detect cradle swinging Radio lost The quality of the radio connection...

Страница 21: ...attery low for the relay outputs The output of the Master alarm should be directly connected to the PLC to stop the machine in case of any alarm condition The Batter low output can be connected to an...

Страница 22: ...ving module in German or English Cycle time Communication cycle time between transmitting and receiving modules The minimum cycle time of 840 ms is only recommended in combination with the 24 VDC powe...

Страница 23: ...s DC 24 V 0 5 A 12 W AC 24 V 0 5 A 62 12 VA Power supply 24 VDC 18 to 36 VDC 10 W max 0 5 A Temperature range 0 to 50 C 32 to 122 F Protection rating IP52 Weight 0 65 kg 1 43 lb Table 11 FMS cradleGUA...

Страница 24: ...y and age of batteries just to name a few Lifetime No of sensors Lifetime 24h operation per day 2 pcs XCell CR9V P 9V batteries each with 1 200mAh 1 135 days 2 80 days 3 55 days 4 45 days Table 13 Typ...

Страница 25: ...adleGUARD Operating Manual and Installation Instructions 24 07 2019 25 7 Dimensions 7 1 FMS cradleGUARD R Receiver Module Figure 15 FMS cradleGUARD R Receiver Module Dimensions FMS_cradleGUARD_BA_Manu...

Страница 26: ...cradleGUARD Operating Manual and Installation Instructions 24 07 2019 26 7 2 FMS cradleGUARD T Transmission Module Figure 16 FMS cradleGUARD T Transmission Module Dimensions FMS_cradleGUARD_BA_Manual...

Страница 27: ...transmission module s Battery empty Replace battery Radio transmission faulty Objects block transmission path Short battery life Battery age or capacitance Use high quality durable batteries We recom...

Страница 28: ...850 60 06 info fms technology com www fms technology com FMS USA Inc 2155 Stonington Avenue Suite 119 Hoffman Estates IL 60169 USA Tel 1 847 519 4400 Fax 1 847 519 4401 fmsusa fms technology com FMS U...

Отзывы: