Operating manual BMGZ 600A
36
Pulse output roller 1/2
Use:
The pulse output of the measuring roller shows a single pulse
after a known feeding quantity. This parameter is used to
determine how many kg correspond to one pulse.
Range:
1, 10, 100, 1000
Default:
100
Unit:
[kg]
Analogue output 1/2
Use:
The analogue output provides a voltage signal (0...10V) and a
current signal alternativ 0...20mA or 4...20mA. The signal is
proportional to the actual flow rate of the measuring roller.
Range:
0...20mA, 4...20mA
Default:
0...20mA
Lowpass output 1/2
Use:
The electronic unit provides a lowpass filter to prevent noise
which is added to the analogue output (flow rate, programmable
signal). This parameter stores the limit frequency. This filter is
independent of the other filters.
Range:
0.1 to
20.0
Default:
10.0
Increment:
0.1
Unit:
[Hz]
Max. Output 1/2
Use:
The flow rate value stored in this parameter provides an analogue
signal of 10V or 20mA. Resolution is 12 bit.
Range:
1.0 to
5000.0
Default:
1000.0
Increment:
0.1
Unit:
[t/h]
Charge number 1/2
Use:
This parameter contains the number of the actual charge. After
each printing of a protocol (refer to „7.8 Operating the printer“),
the value is incremented by 1.
Here, the charge number may be manually reset to zero.
Range:
0
to
100000
Increment:
1
Unit:
[-]
Pre detect charge roller 1 (BMGZ611A)
Use:
If the difference between
Ref. charge roller 1
and actual charge
weight of roller 1 is smaller than the value stored in this
parameter, the relay 3 (terminals 213/214) will be activated.
With this, for ex. a kind of braking ramp or shutting of the silo can
be programmed.
Содержание BMGZ 610A
Страница 6: ...Operating manual BMGZ 600A 6 components in italic letters are option...
Страница 16: ...Operating manual BMGZ 600A 16 Repeat the procedure for the 2nd side disk...
Страница 18: ...Operating manual BMGZ 600A 18 8 Replace the earth cable and all the cables with connectors back to place...
Страница 20: ...Operating manual BMGZ 600A 20 6 6 Wiring Information fig 16 Terminal arrangement on terminal board B600007...
Страница 45: ...Operating manual BMGZ 600A 45 fig 31 Flat measuring roller B400013e...