Adjusting Correction Speed [AdjSpeed]
Purpose:
This parameter determines the maximum used correction speed.
Range:
1 bis
100
Default:
100
Increment:
1 Unit:
[%]
Power Modes [Power ON]
Purpose:
This parameter determines the operation mode after power on.
The user can choose between three behaviours.
Setting:
[Manual]
Purpose:
The controller goes to Manual Operation Mode after power on.
Setting:
Automatic [Auto]
Purpose:
The controller goes to Automatic Operation Mode after power on.
Setting:
Last Setting Used [Last Set]
Purpose:
The controller restores the operation mode that was previously
chosen before power off.
Behaviour when leaving Automatic Mode [Auto
→
Man]
Purpose:
This parameter determines the behaviour of the controller leaving
the automatic mode.
The user can choose between two behaviours.
Setting:
[Manual]
Purpose:
The controller stops guiding. The web guide is locked at the
current position (Manual Mode).
Setting:
[Centre]
Purpose:
The controller stops guiding. Afterwards the web guide moves to
the centre.