Operating Manual BKS015
26.11.2018
30
Right Limit [RightLim]
Purpose: The
[RightLim] parameter is only used with the position detection system
based on hall sensors. For all other position detection system this
parameter is not used and hence not displayed. The parameter limits the
maximum travel to the right side of the actuator spindle in motor steps
(measured from the left reference position). In the operation or in
manual mode this limit will never be exceeded
Range: 0 to
10’000
Default: Factory setting
Increment: 1
Unit: [Step]
Drive Direction [DriveDir]
Purpose:
This parameter determines the guiding orientation of the controller.
Usually stepper motors turn clockwise. This setting changes the turning
direction of the motor. There are two other possibilities to change the
guiding direction:
The user can choose between two settings
Setting:
[Standard]
Purpose:
[
Standard]
is chosen when standard motors and standard frames are
used.
Setting:
[Invers]
Purpose:
[
Invers] is chosen when motors are used that turn anticlockwise.
9.3
Reset to Default Parameter Set
Factory settings of your BKS015.EIP web guide controller can be re-established by
pressing a combination of two keys.
Hold the two keys
+
while powering -up the controller