Operating Manual BKS015
26.11.2018
11
5
Configuring the System
After having mounted and wired the web guide on the machine, the system can now
be configured to the specific requirements of the application.
5.1
Powering up the BKS015.EIP
1.
Make sure the power supply delivers a voltage of 18…36 VDC (Vnom= 24V)
2.
Check, if the web is in the detection range of the sensors.
3.
Switch-on your power supply
4.
The web guide starts-up in Manual Operating Mode.
5.2
Adjustment of the Sensors
Align sensor axis to the web edge:
Loosen the fixing nut on the bracket and adjust the sensor. Fix the sensor in the
new position. The sensor will be properly positioned, if the web edge goes through
the sensor axis (center of active window; ref. to Fig. 5).
Fig 5: Alignment of the sensor axis to the web edge
K100004e
.