SAFETY
INFORMATION

 DANGER: Carbon monoxide

poisoning may lead to death!

Carbon Monoxide Poisoning:

 

Early signs

of carbon monoxide poisoning resemble the
flu, with headaches, dizziness, or nausea. If you
have these signs, the fireplace may not be
working properly. Get fresh air at once! Have
fireplace serviced. Some people are more af-
fected by carbon monoxide than others. These
include pregnant women, people with heart or
lung disease or anemia, those under the influ-
ence of alcohol, and those at high altitudes.

Natural Gas:

 Natural gas is odorless. An

odor-making agent is added to the gas. The
odor helps you detect a gas leak. However,
the odor added to the gas can fade. Gas may
be present even though no odor exists.

Make certain you read and understand all
warnings. Keep this manual for reference. It
is your guide to safe and proper operation of
this fireplace.

 WARNINGS

IMPORTANT: Read this owner’s
manual carefully and completely
before trying to assemble, operate,
or service this fireplace. Improper
use of this fireplace can cause seri-
ous injury or death from burns, fire,
explosion, electrical shock, and
carbon monoxide poisoning.

1.

This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases.

2.

If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do

not use any phone in your building

• immediately call your gas supplier

from a neighbor’s phone. Follow the
gas supplier’s instructions

• if you cannot reach your gas supplier,

call the fire department

3.

This fireplace shall not be installed in
a bedroom or bathroom.

4.

Do not use this fireplace as a wood-
burning fireplace. Use only the logs
provided with the fireplace.

5.

Do not add extra logs or ornaments
such as pine cones, vermiculite, or rock
wool. Using these added items can
cause sooting. Do not add lava rock
around base. Rock and debris could fall
into the control area of fireplace.

6.

This fireplace is designed to be smoke-
less. If logs ever appear to smoke, turn
off fireplace and call a qualified ser-
vice person. 

Note:

 During initial op-

eration, slight smoking could occur due
to log curing and fireplace burning
manufacturing residues.

7.

To prevent the creation of soot, follow
the instructions in Cleaning and Main-
tenance, 
page 18.

8.

Before using furniture polish, wax, car-
pet cleaner, or similar products, turn
heater off. If heated, the vapors from
these products may create a white pow-
der residue within burner box or on
adjacent walls or furniture.

9.

This fireplace needs fresh air ventila-
tion to run properly. This fireplace has
an Oxygen Depletion Sensing (ODS)
safety shutoff system. The ODS shuts
down the fireplace if not enough fresh
air is available. See Air for Combus-
tion and Ventilation,
 pages 4 through
6. If fireplace keeps shutting off, see
Troubleshooting, pages 19 through 21.

10. Do not run fireplace

• where flammable liquids or vapors

are used or stored

• under dusty conditions

11. Do not use this fireplace to cook food

or burn paper or other objects.

12. Do not use fireplace if any part has been

exposed to or under water. Immediately
call a qualified service technician to
inspect the fireplace and to replace any
part of the control system and any gas
control which has been under water.

13. Do not operate fireplace if any log is

broken. Do not operate fireplace if a
log is chipped (dime-sized or larger).

14. Turn fireplace off and let cool before

servicing. Only a qualified service per-
son should service and repair fireplace.

15. Operating fireplace above elevations of

4,500 feet could cause pilot outage.

 WARNING: Any change to

this heater or its controls can be
dangerous.

 WARNING: Do not allow fans

to blow directly into the fireplace.
Avoid any drafts that alter burner
flame patterns. Ceiling fans can
create drafts that alter burner
flame patterns. Altered burner
patterns can cause sooting.

 WARNING: Do not use a

blower insert, heat exchanger
insert, or other accessory not ap-
proved for use with this heater.

Due to high temperatures, the
appliance should be located out
of traffic and away from furniture
and draperies.

Do not place clothing or other
flammable material on or near
the appliance. Never place any
objects on the heater.

Fireplace front and screen be-
come very hot when running fire-
place. Keep children and adults
away from hot surfaces to avoid
burns or clothing ignition. Fire-
place will remain hot for a time
after shut-down. Allow surfaces
to cool before touching.

Carefully supervise young children
when they are in the room with
fireplace. When using the optional
hand-held remote accessory, keep
selector switch in the off position
to prevent children from turning
on burners with remote.

You must operate this fireplace
with the fireplace screen and
hood in place. Make sure fire-
place screen and hood are in
place before running fireplace.

Keep the appliance area clear and
free from combustible materials,
gasoline, and other flammable va-
pors and liquids.

Содержание FPVF33NR

Страница 1: ...adjustment alteration ser vice ormaintenancecancause injuryorpropertydamage Re fer to this manual for correct installation and operational procedures For assistance or additional information consult a...

Страница 2: ...er or similar products turn heater off If heated the vapors from these products may create a white pow der residue within burner box or on adjacent walls or furniture 9 This fireplace needs fresh air...

Страница 3: ...fireplace screen Remove and discard these screws Lift fireplace screen up and pull out to remove 3 Remove protective packaging applied to logs log base assembly and fireplace 4 Remove fireplace hood f...

Страница 4: ...s provisions are provided for adequate combustion and ventilation air Adjoining rooms are communicating only iftherearedoorlesspassagewaysorventila tion grills between them PRODUCT FEATURES OPERATION...

Страница 5: ...________________ Btu Hr Other gas appliances ___________________ Btu Hr Total ___________________ Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors an...

Страница 6: ...two per manent openings one within 12 of the ceiling and one within 12 of the floor Connecttheseitemsdirectlytotheoutdoors orspacesopentotheoutdoors Thesespaces include attics and crawl spaces Follow...

Страница 7: ...n the adjusting plate with slotted screwdriver 7 Repeat steps 1 through 6 for other side 8 Tighten trim hanging screws 10 x 6 25 shoulder into holes in cabinets Place the assembled trim onto fireplace...

Страница 8: ...ng wood screws Countersink screw heads and putty over 5 Route flexible gas line through access hole in hearth base INSTALLATION Continued 6 Center cabinet mantel on hearth base see Figure 10 Make sure...

Страница 9: ...e fireplace to clear thermostat valve 6 Replace bottom of firebox 7 Install gas piping to fireplace location This installation includes an approved flexible gas line if allowed by local codes after th...

Страница 10: ...ion If placing mantel above built in fireplace youmustmeetminimumclearancebetween mantel shelf and top of fireplace opening Figure 16 Minimum Mantel Clearances for Built In Installation INSTALLATION C...

Страница 11: ...toff Valve With 1 8 NPT Tap 3 Minimum From Gas Meter 5 W C to 10 5 W C Pressure Pipe Cap Tee Nipple Joint Sediment Trap Installation Items Needed 5 16 hex socket wrench or nut driver Phillips screwdri...

Страница 12: ...er 4 Check all joints of gas supply piping system Apply mixture of liquid soap and water to gas joints Bubbles form ing show a leak 5 Correct all leaks at once 6 Reconnect fireplace and equipment shut...

Страница 13: ...pping notches of fireplace screen over screws on front of fireplace see Figure 24 WARNING You must operate this fireplace with the fireplace screen in place Make sure fire place screen is in place bef...

Страница 14: ...battery cover onto remote con trol unit Battery Cover Terminal Wires Remote Control Unit Valve White Wire From Receiver INSTALLING 9 VOLT BATTERIES Two 9 volt batteries not included are re quired to o...

Страница 15: ...witch to OFF position 4 Press in and turn control knob clock wise to the OFF position 5 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follo...

Страница 16: ...ob anywhere between HI and LO SlidetheselectorswitchtotheRE MOTEposition seeFigure33 Note Theburners maylightifhand heldre mote ON button was on when selector switch was last turned off You can now tu...

Страница 17: ...ows You to Choose the Auto Setting The Log Heater will Automatically Cycle between Pilot and the Heat Setting that has been Selected IMPORTANT This remote control has been specially engineered to take...

Страница 18: ...ealsorecommendthatyoukeeptheburner tubeandpilotassemblycleanandfreeofdust and dirt To clean these parts we recommend using compressed air no greater than 30 PSI Yourlocalcomputerstore hardwarestore or...

Страница 19: ...Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base panel 4 Re...

Страница 20: ...lation requirements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local natural gas company 3 Observe...

Страница 21: ...ntilate room Stop using odor causing products while fire place is running 2 Locate and correct all leaks see Check ing Gas Connections page 12 1 Open window and or door for ventilation 2 Contact local...

Страница 22: ...ct your local natural gas supplier AUTO OFF ON Thermopile WIRING DIAGRAM Note For proper operation of optional ac cessories the wires from the switch to the controlmustbeconnectedexactlyasshown REPLAC...

Страница 23: ...16 BLOWER ACCESSORIES GA3700 AND GA3700T Manualvariablecontrolandautomaticther mostat control AUTO ON OFF COOLE R WARMER TEMP RECEIVER AND HAND HELD THERMOSTAT REMOTE CONTROL KIT GHRCT SERIES For all...

Страница 24: ...105271 UNVENTED NATURAL GAS FIREPLACE ILLUSTRATED PARTS BREAKDOWN REMOTE READY MODEL FPVF33NR 17 27 4 O F F P I L O T O N H I L O 8 12 26 7 6 4 3 2 1 5 9 28 14 13 25 15 16 21 11 10 19 20 19 23 24 22...

Страница 25: ...Burner Orifice Injector 1 8 102772 01 Burner 2 9 M11084 38 Screw 8 x 38 2 10 104236 01CK Painted Base Assy 1 11 M12461 26 Screw 10 x 32 4 12 104238 01CK Firebox Bottom 1 13 103284 03 Wiring Harness 1...

Страница 26: ...26 105271 UNVENTED NATURAL GAS FIREPLACE ILLUSTRATED PARTS BREAKDOWN FIREPLACE FPVF33NR 4 11 14 18 19 20 17 8 14 9 3 14 9 9 2 1 6 7 10 14 12 5 14 13 16 15...

Страница 27: ...Head Screw 10 9 6 104239 01CK Top Front Louver 1 7 101712 02 Firebox Hood 1 8 101348 01 Firebox Support 2 9 099230 02 Shoulder Screw 4 10 101872 03 Firebox Top 1 11 101346 01CK Outer Base 1 12 101838...

Страница 28: ...tsrelatedtorepairingadefectiveheaterwillbetheresponsibilityoftheowner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXP...