background image

14

105271

UNVENTED NATURAL GAS FIREPLACE

INSTALLATION

Continued

OPTIONAL WIRELESS HAND-
HELD REMOTE CONTROL
ACCESSORIES
(GHRC and GHRCT Series)

Installing Remote Receiver Unit

1.

Disconnect switch wires from the con-
trol valve.

2.

Remove screws attaching switchplate.

3.

Remove switch plate (see Figure 25).
Discard after removing.

4.

Install remote receiver unit onto gas log
heater base using mounting clips.

5.

Push clips firmly into place (see Figure 26).

6.

Connect wires as shown in Figure 27.

Figure 25 - Switch Plate and Wiring
Harness

Figure 28 - Installing Battery in Remote
Receiver

Figure 26 - Installing Remote Receiver

Installing 9-Volt Battery in Hand-
Held Remote Control Unit

1.

Remove battery cover on back of re-
mote control unit.

2.

Attach terminal wires to the battery.
Place battery into the battery housing.

3.

Replace battery cover onto remote con-
trol unit.

Battery
Cover

Terminal
Wires

Remote
Control Unit

Valve

White Wire
From Receiver

INSTALLING 9-VOLT
BATTERIES

Two 9-volt batteries (not included) are re-
quired to operate this heater with the wire-
less hand held remote control set. Install one
battery in the receiver and one in the hand-
held remote control unit. 

Note:

 Only use

alkaline batteries.

Installing 9-Volt Battery in
Receiver

1.

Locate back of receiver under front
burner of heater.

2.

Locate the battery clip mounted on the
back of the receiver.

3.

Slide a 9-volt battery through the clip.

4.

Attach the terminal wires to the battery.

Battery Clip

9-Volt Battery

Terminal Wires

Remote
Receiver

Figure 29 - Installing Battery in Hand-
Held Remote Control Unit

9-Volt
Battery

Battery
Housing

Screw

Switch
Plate

Wires

Remote
Switch
Bracket

Ignitor

Remote Receiver

Mounting Clips

Figure 27 - Connecting Wires

Red Wire From
Receiver

Figure 30 - Installing Battery in Hand-Held
Remote Control Unit (GHRCTA Series
Only)

Remote
Control
Unit

Содержание FPVF33NR

Страница 1: ...adjustment alteration ser vice ormaintenancecancause injuryorpropertydamage Re fer to this manual for correct installation and operational procedures For assistance or additional information consult a...

Страница 2: ...er or similar products turn heater off If heated the vapors from these products may create a white pow der residue within burner box or on adjacent walls or furniture 9 This fireplace needs fresh air...

Страница 3: ...fireplace screen Remove and discard these screws Lift fireplace screen up and pull out to remove 3 Remove protective packaging applied to logs log base assembly and fireplace 4 Remove fireplace hood f...

Страница 4: ...s provisions are provided for adequate combustion and ventilation air Adjoining rooms are communicating only iftherearedoorlesspassagewaysorventila tion grills between them PRODUCT FEATURES OPERATION...

Страница 5: ...________________ Btu Hr Other gas appliances ___________________ Btu Hr Total ___________________ Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors an...

Страница 6: ...two per manent openings one within 12 of the ceiling and one within 12 of the floor Connecttheseitemsdirectlytotheoutdoors orspacesopentotheoutdoors Thesespaces include attics and crawl spaces Follow...

Страница 7: ...n the adjusting plate with slotted screwdriver 7 Repeat steps 1 through 6 for other side 8 Tighten trim hanging screws 10 x 6 25 shoulder into holes in cabinets Place the assembled trim onto fireplace...

Страница 8: ...ng wood screws Countersink screw heads and putty over 5 Route flexible gas line through access hole in hearth base INSTALLATION Continued 6 Center cabinet mantel on hearth base see Figure 10 Make sure...

Страница 9: ...e fireplace to clear thermostat valve 6 Replace bottom of firebox 7 Install gas piping to fireplace location This installation includes an approved flexible gas line if allowed by local codes after th...

Страница 10: ...ion If placing mantel above built in fireplace youmustmeetminimumclearancebetween mantel shelf and top of fireplace opening Figure 16 Minimum Mantel Clearances for Built In Installation INSTALLATION C...

Страница 11: ...toff Valve With 1 8 NPT Tap 3 Minimum From Gas Meter 5 W C to 10 5 W C Pressure Pipe Cap Tee Nipple Joint Sediment Trap Installation Items Needed 5 16 hex socket wrench or nut driver Phillips screwdri...

Страница 12: ...er 4 Check all joints of gas supply piping system Apply mixture of liquid soap and water to gas joints Bubbles form ing show a leak 5 Correct all leaks at once 6 Reconnect fireplace and equipment shut...

Страница 13: ...pping notches of fireplace screen over screws on front of fireplace see Figure 24 WARNING You must operate this fireplace with the fireplace screen in place Make sure fire place screen is in place bef...

Страница 14: ...battery cover onto remote con trol unit Battery Cover Terminal Wires Remote Control Unit Valve White Wire From Receiver INSTALLING 9 VOLT BATTERIES Two 9 volt batteries not included are re quired to o...

Страница 15: ...witch to OFF position 4 Press in and turn control knob clock wise to the OFF position 5 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follo...

Страница 16: ...ob anywhere between HI and LO SlidetheselectorswitchtotheRE MOTEposition seeFigure33 Note Theburners maylightifhand heldre mote ON button was on when selector switch was last turned off You can now tu...

Страница 17: ...ows You to Choose the Auto Setting The Log Heater will Automatically Cycle between Pilot and the Heat Setting that has been Selected IMPORTANT This remote control has been specially engineered to take...

Страница 18: ...ealsorecommendthatyoukeeptheburner tubeandpilotassemblycleanandfreeofdust and dirt To clean these parts we recommend using compressed air no greater than 30 PSI Yourlocalcomputerstore hardwarestore or...

Страница 19: ...Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base panel 4 Re...

Страница 20: ...lation requirements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local natural gas company 3 Observe...

Страница 21: ...ntilate room Stop using odor causing products while fire place is running 2 Locate and correct all leaks see Check ing Gas Connections page 12 1 Open window and or door for ventilation 2 Contact local...

Страница 22: ...ct your local natural gas supplier AUTO OFF ON Thermopile WIRING DIAGRAM Note For proper operation of optional ac cessories the wires from the switch to the controlmustbeconnectedexactlyasshown REPLAC...

Страница 23: ...16 BLOWER ACCESSORIES GA3700 AND GA3700T Manualvariablecontrolandautomaticther mostat control AUTO ON OFF COOLE R WARMER TEMP RECEIVER AND HAND HELD THERMOSTAT REMOTE CONTROL KIT GHRCT SERIES For all...

Страница 24: ...105271 UNVENTED NATURAL GAS FIREPLACE ILLUSTRATED PARTS BREAKDOWN REMOTE READY MODEL FPVF33NR 17 27 4 O F F P I L O T O N H I L O 8 12 26 7 6 4 3 2 1 5 9 28 14 13 25 15 16 21 11 10 19 20 19 23 24 22...

Страница 25: ...Burner Orifice Injector 1 8 102772 01 Burner 2 9 M11084 38 Screw 8 x 38 2 10 104236 01CK Painted Base Assy 1 11 M12461 26 Screw 10 x 32 4 12 104238 01CK Firebox Bottom 1 13 103284 03 Wiring Harness 1...

Страница 26: ...26 105271 UNVENTED NATURAL GAS FIREPLACE ILLUSTRATED PARTS BREAKDOWN FIREPLACE FPVF33NR 4 11 14 18 19 20 17 8 14 9 3 14 9 9 2 1 6 7 10 14 12 5 14 13 16 15...

Страница 27: ...Head Screw 10 9 6 104239 01CK Top Front Louver 1 7 101712 02 Firebox Hood 1 8 101348 01 Firebox Support 2 9 099230 02 Shoulder Screw 4 10 101872 03 Firebox Top 1 11 101346 01CK Outer Base 1 12 101838...

Страница 28: ...tsrelatedtorepairingadefectiveheaterwillbetheresponsibilityoftheowner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXP...

Отзывы: