16
105271
UNVENTED NATURAL GAS FIREPLACE
IMPORTANT
: Do not leave the selec-
tor switch in the REMOTE position
when the pilot is not lit. This will
drain the battery.
IMPORTANT:
Be sure to press the
ON/OFF buttons on the hand-held
remote control unit for up to 3 sec-
onds to assure proper operation.
GHRC Series Operation:
2a. Press the ON/OFF button to turn the
burners on and off. When turning
burners off, the pilot will remain lit.
GHRCTA Series Operation:
2b. Press the AUTO/ON/OFF button on
the hand-held remote control (see Fig-
ure 34, page 17). The lights to the left
of the button will show AUTO, ON,
or OFF.
• In the ON mode, the burners will
ignite. The heater is in manual
mode when ON is lit.
• In the AUTO mode, the thermostat
in the hand-held remote unit con-
trols the room temperature. To in-
crease the room temperature, press
the top arrow of the TEMP button.
To lower the room temperature,
press the bottom arrow of the
TEMP button. At higher settings
the heater will run longer.
WARNING: Make sure the
selector switch is in the OFF po-
sition when you are away from
home for long periods of time.
Heater will come on automati-
cally with selector switch in the
ON position.
Ignitor Electrode
Pilot Burner
Figure 32 - Pilot
TO TURN OFF GAS
TO APPLIANCE
MANUAL LIGHTING
PROCEDURE
1.
Follow steps 1 through 6 under Light-
ing Instructions, page 15.
2.
Depress control knob and light pilot
with match.
3.
Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow steps 9 through 11, page 15.
1.
After lighting, let pilot flame burn for
about one minute. Turn control knob
to ON position. Adjust flame adjust-
ment knob anywhere between HI and
LO. Slide the selector switch to the RE-
MOTE position (see Figure 33).
Note:
The burners may light if hand-held re-
mote ON button was on when selector
switch was last turned off. You can
now turn the burners on and off with
the hand-held remote control unit.
NOTICE: You must light the pilot
before using the hand-held re-
mote control unit. See
Lighting
Instructions on page 15.
OPERATING
FIREPLACE
Continued
Shutting Off Heater
1.
Turn control knob clockwise
to the OFF position.
2a. Set selector switch in the OFF position.
2b.
If Using Optional Hand-Held Re-
mote:
Set selector switch in the OFF
position to keep from draining battery.
Shutting Off Burners Only (pilot
stays lit)
You may shut off the burners and keep
the pilot lit by doing one of the following:
• Turn control knob clockwise
to the PILOT position.
• Use remote control manual OFF button.
• Set selector switch in the OFF position.
OPTIONAL REMOTE
OPERATION
Thermostat Control Operation
(Optional GHRCTA Series Only) The
thermostat control setting on the remote
control unit can be set to any comfort level
between WARMER and COOLER. The
burners will turn on and off automatically
to maintain the comfort level you select.
The ideal comfort setting will vary by
household depending upon the amount of
space to be heated, the output of the cen-
tral heating system, etc.
For wall thermostat operation, follow in-
struction supplied with thermostat ac-
cessory GWMT1. For wall switch opera-
tion follow instructions supplied with
GWMS2.
Note:
All remote control accessories must
be purchased separately (see Accessories,
page 23). Follow instructions included
with the remote control.
O
FF
PILO
T
O
N
L O
I H
ON
OFF
REMOTE
Figure 33 - Setting the Selector Switch, Control Knob, and Flame Adjustment Knob for
Remote Operation
Selector Switch in
Remote Position
(Optional Remote
Control)
Control Knob in On Position
Flame Adjustment Knob