background image

15

105271

OWNER’S MANUAL

LIGHTING

INSTRUCTIONS

OPERATING
FIREPLACE

FOR YOUR SAFETY

READ BEFORE

LIGHTING

 WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

A. This appliance has a pilot which must

be lighted by hand. When lighting the
pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all

around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.

WHAT TO DO IF YOU SMELL
GAS
• Do not try to light any appliance.
• Do not touch any electric switch;

do not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow
the gas supplier’s instructions.

• If you cannot reach your gas sup-

plier, call the fire department.

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.

D. Do not use this appliance if any part

has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been un-
der water.

 WARNING: You must operate

this heater with the fireplace
screen in place. Make sure fire-
place screen is in place before
running heater.

NOTICE: During initial operation
of new heater, burning logs will
give off a paper-burning smell.
Open damper or window to vent
smell. This will only last a few
hours.

1.

STOP! Read the safety information,
column 1.

2.

Make sure equipment shutoff valve
is fully open.

3.

Set switch to OFF position.

4.

Press in and turn control knob clock-
wise 

  to the OFF position.

5.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation. If you don’t smell gas, go
to the next step.

6.

Press in and turn control knob coun-
terclockwise  

  to the PILOT

position. Press in control knob for
five (5) seconds (see Figure 31).

 WARNING: Burners will come

on automatically within one
minute when the selector switch
is in the ON position after the
pilot is lit.

 CAUTION: Do not try to adjust

heating levels by using the equip-
ment shutoff valve.

Note: 

You may be running this

heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds or more. This will al-
low air to bleed from the gas system.

7.

With control knob pressed in, press
and release ignitor button. This will
light pilot. The pilot is attached to the
front burner. If needed, keep press-
ing ignitor button until pilot lights.

Note:

 If pilot does not stay lit, con-

tact a qualified service person or gas
supplier for repairs. Until repairs are
made, light pilot with match. To light
pilot with match, see Manual Light-
ing Procedure
 on page 16.

8.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
• If control knob does not pop out

when released, contact a qualified
service person or gas supplier for
repairs.

Note:

 If pilot goes out, repeat steps

4 through 8.

9.

Slightly push in and turn control
knob counterclockwise  

 to

the ON position.

10. Wait one minute and switch selector

switch to the ON position to light
burners.

11. Set flame adjustment knob to any

level between HI and LO.

O

F

F

PIL

OT

O

N

L O

I H

AUTO
OFF
ON

Figure 31 - Control Knob and Ignitor Button Location (Shown as Supplied,
No Control Options)

Control Knob

Ignitor Button

 Selector Switch

Flame Adjustment
Knob

Continued

Содержание FPVF33NR

Страница 1: ...adjustment alteration ser vice ormaintenancecancause injuryorpropertydamage Re fer to this manual for correct installation and operational procedures For assistance or additional information consult a...

Страница 2: ...er or similar products turn heater off If heated the vapors from these products may create a white pow der residue within burner box or on adjacent walls or furniture 9 This fireplace needs fresh air...

Страница 3: ...fireplace screen Remove and discard these screws Lift fireplace screen up and pull out to remove 3 Remove protective packaging applied to logs log base assembly and fireplace 4 Remove fireplace hood f...

Страница 4: ...s provisions are provided for adequate combustion and ventilation air Adjoining rooms are communicating only iftherearedoorlesspassagewaysorventila tion grills between them PRODUCT FEATURES OPERATION...

Страница 5: ...________________ Btu Hr Other gas appliances ___________________ Btu Hr Total ___________________ Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors an...

Страница 6: ...two per manent openings one within 12 of the ceiling and one within 12 of the floor Connecttheseitemsdirectlytotheoutdoors orspacesopentotheoutdoors Thesespaces include attics and crawl spaces Follow...

Страница 7: ...n the adjusting plate with slotted screwdriver 7 Repeat steps 1 through 6 for other side 8 Tighten trim hanging screws 10 x 6 25 shoulder into holes in cabinets Place the assembled trim onto fireplace...

Страница 8: ...ng wood screws Countersink screw heads and putty over 5 Route flexible gas line through access hole in hearth base INSTALLATION Continued 6 Center cabinet mantel on hearth base see Figure 10 Make sure...

Страница 9: ...e fireplace to clear thermostat valve 6 Replace bottom of firebox 7 Install gas piping to fireplace location This installation includes an approved flexible gas line if allowed by local codes after th...

Страница 10: ...ion If placing mantel above built in fireplace youmustmeetminimumclearancebetween mantel shelf and top of fireplace opening Figure 16 Minimum Mantel Clearances for Built In Installation INSTALLATION C...

Страница 11: ...toff Valve With 1 8 NPT Tap 3 Minimum From Gas Meter 5 W C to 10 5 W C Pressure Pipe Cap Tee Nipple Joint Sediment Trap Installation Items Needed 5 16 hex socket wrench or nut driver Phillips screwdri...

Страница 12: ...er 4 Check all joints of gas supply piping system Apply mixture of liquid soap and water to gas joints Bubbles form ing show a leak 5 Correct all leaks at once 6 Reconnect fireplace and equipment shut...

Страница 13: ...pping notches of fireplace screen over screws on front of fireplace see Figure 24 WARNING You must operate this fireplace with the fireplace screen in place Make sure fire place screen is in place bef...

Страница 14: ...battery cover onto remote con trol unit Battery Cover Terminal Wires Remote Control Unit Valve White Wire From Receiver INSTALLING 9 VOLT BATTERIES Two 9 volt batteries not included are re quired to o...

Страница 15: ...witch to OFF position 4 Press in and turn control knob clock wise to the OFF position 5 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follo...

Страница 16: ...ob anywhere between HI and LO SlidetheselectorswitchtotheRE MOTEposition seeFigure33 Note Theburners maylightifhand heldre mote ON button was on when selector switch was last turned off You can now tu...

Страница 17: ...ows You to Choose the Auto Setting The Log Heater will Automatically Cycle between Pilot and the Heat Setting that has been Selected IMPORTANT This remote control has been specially engineered to take...

Страница 18: ...ealsorecommendthatyoukeeptheburner tubeandpilotassemblycleanandfreeofdust and dirt To clean these parts we recommend using compressed air no greater than 30 PSI Yourlocalcomputerstore hardwarestore or...

Страница 19: ...Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base panel 4 Re...

Страница 20: ...lation requirements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local natural gas company 3 Observe...

Страница 21: ...ntilate room Stop using odor causing products while fire place is running 2 Locate and correct all leaks see Check ing Gas Connections page 12 1 Open window and or door for ventilation 2 Contact local...

Страница 22: ...ct your local natural gas supplier AUTO OFF ON Thermopile WIRING DIAGRAM Note For proper operation of optional ac cessories the wires from the switch to the controlmustbeconnectedexactlyasshown REPLAC...

Страница 23: ...16 BLOWER ACCESSORIES GA3700 AND GA3700T Manualvariablecontrolandautomaticther mostat control AUTO ON OFF COOLE R WARMER TEMP RECEIVER AND HAND HELD THERMOSTAT REMOTE CONTROL KIT GHRCT SERIES For all...

Страница 24: ...105271 UNVENTED NATURAL GAS FIREPLACE ILLUSTRATED PARTS BREAKDOWN REMOTE READY MODEL FPVF33NR 17 27 4 O F F P I L O T O N H I L O 8 12 26 7 6 4 3 2 1 5 9 28 14 13 25 15 16 21 11 10 19 20 19 23 24 22...

Страница 25: ...Burner Orifice Injector 1 8 102772 01 Burner 2 9 M11084 38 Screw 8 x 38 2 10 104236 01CK Painted Base Assy 1 11 M12461 26 Screw 10 x 32 4 12 104238 01CK Firebox Bottom 1 13 103284 03 Wiring Harness 1...

Страница 26: ...26 105271 UNVENTED NATURAL GAS FIREPLACE ILLUSTRATED PARTS BREAKDOWN FIREPLACE FPVF33NR 4 11 14 18 19 20 17 8 14 9 3 14 9 9 2 1 6 7 10 14 12 5 14 13 16 15...

Страница 27: ...Head Screw 10 9 6 104239 01CK Top Front Louver 1 7 101712 02 Firebox Hood 1 8 101348 01 Firebox Support 2 9 099230 02 Shoulder Screw 4 10 101872 03 Firebox Top 1 11 101346 01CK Outer Base 1 12 101838...

Страница 28: ...tsrelatedtorepairingadefectiveheaterwillbetheresponsibilityoftheowner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXP...

Отзывы: