background image

www.fmiproducts.com

125010-01A

20

CLEANING AND MAINTENANCE

4.  Check injector holder located at the end of 

the burner tube again. Remove any large 

particles of dust, dirt, lint or pet hair with 

a soft cloth or vacuum cleaner nozzle.

5.  Blow air into the primary air holes on the 

injector holder.

6.  In case any large clumps of dust have now 

been pushed into the burner repeat steps 

3 and 4.

Clean pilot assembly also. A yellow tip on the 

pilot flame indicates dust and dirt in the pilot 

assembly. There is a small pilot air inlet hole 

about 2" from where the pilot flame comes out 

of the pilot assembly (see Figure 30). With the 

unit off, lightly blow air through the air inlet 

hole. You may blow through a drinking straw 

if compressed air is not available.

Figure 29 - Injector Holder On Outlet 

Burner Tube

Burner 

Tube

Injector Holder

Primary Air 

Inlet Holes

Ports/Slots

Figure 30 - Pilot Inlet Air Hole (Your pilot 

may vary from pilot shown)

Pilot Air 

Inlet Hole

Pilot Assembly

LOGS

•  If  you  remove  logs  for  cleaning,  refer  to 

Installing Logs

, page 16, to properly replace 

logs.

•  Replace log(s) if broken or chipped (dime-

sized or larger).

MAIN BURNER

Periodically inspect all burner flame holes with 

the heater running. All slotted burner flame 

holes should be open with yellow flame pres

-

ent. All round burner flame holes should be 

open with a small blue flame present. Some 

burner flame holes may become blocked by 

debris or rust, with no flame present. If so, 

turn off heater and let cool. Remove blockage, 

blocked burner flame holes will create soot.

  WARNING:  Turn  off  heater 

and let cool before cleaning.

  CAUTION:  You  must  keep 

control  areas,  burners  and 

circulating  air  passageways 

of  heater  clean.  Inspect  these 

areas of heater before each use. 

Have  heater  inspected  yearly 

by  a  qualified  service  person. 

Heater may need more frequent 

cleaning  due  to  excessive  lint 

from carpeting, pet hair, bedding 

material, etc.

 WARNING: Failure to keep 

the  primary  air  opening(s)  of 

the burner(s) clean may result in 

sooting and property damage.

BURNER INjECTOR HOLDER AND 

PILOT AIR INLET HOLE

The primary air inlet holes allow the proper 

amount of air to mix with the gas. This provides 

a clean burning flame. Keep these holes clear 

of dust, dirt, lint and pet hair. Clean these air in

-

let holes prior to each heating season. Blocked 

air holes will create soot. We recommend that 

you clean the unit every three months during 

operation and have heater inspected yearly by 

a qualified service person.

We also recommend that you keep the burner 

tube and pilot assembly clean and free of dust 

and dirt. To clean these parts we recommend 

using compressed air no greater than 30 PSI. 

Your local computer store, hardware store or 

home center may carry compressed air in a 

can. If using compressed air in a can, please 

follow the directions on the can. If you don’t 

follow directions on the can, you could dam

-

age the pilot assembly.

1.  Shut off unit, including pilot. Allow unit to 

cool for at least thirty minutes.

2.  Inspect burner, pilot and primary air inlet 

holes on injector holder for dust and dirt 

(see Figure 29).

3.  Blow air through the ports/slots and holes 

in the burner.

Содержание EzC18N

Страница 1: ...lding Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference UNVENTED VENT FREE GAS LOG HEATER OWNER ...

Страница 2: ... burn ing masonry or UL127 factory built fireplace or in a listed ventless firebox enclosure It is design cer tifiedfortheseinstallations in accordance with ANSI Z21 11 2 Exception Donot install this appliance in a factory built fireplace that includes instructions stat ing it has not been tested or should not be used with unvented gas logs WARNING This is an unvented gas fired heat er It uses air...

Страница 3: ...ists Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this fireplace WARNING Any change to this heater or its controls can be dangerous WARNING Do not use a blower insert heat exchanger insertorotheraccessorynotap proved for use with this heater SAFETY Continued WARNING Donotallowfans toblowdirectlyintothefireplace Av...

Страница 4: ...d If you operate heater with doors closed heat buildup inside fireplace will cause glass to burst Make sure there are no obstructions across openings of fireplace 8 To prevent the creation of soot follow the instructions in Cleaning and Maintenance page 20 9 Before using furniture polish wax carpet cleaner or similar products turn heater off If heated the vapors from these prod ucts may create a w...

Страница 5: ...ter base assembly from carton Note Do not pick up heater base assem bly by burners This could damage heater Always handle base assembly by grate 2 Remove all protective packaging applied to logs and heater for shipment 3 Check heater for any shipping damage If heater is damaged call FMI PRODUCTS LLC at 1 866 328 4537 for replacement parts before returning to dealer Product Features Operation This ...

Страница 6: ...et to determine if you have a confined or unconfined space Space Includes the room in which you will install fireplace plus any adjoining rooms with door less passageways or ventilation grills between the rooms WARNING This heater shall notbeinstalledinaroomorspace unlesstherequiredvolumeofin door combustion air is provided by the method described in the National Fuel Gas Code ANSI Z223 1 NFPA54 t...

Страница 7: ... space because the actual Btu Hr used is more than the maximum Btu Hr the space can sup port You must provide additional fresh air Your options are as follows A Rework worksheet adding the space of an adjoining room If the extra space provides an unconfined space remove door to adjoining room or add ventilation grills between rooms See Ventilation Air From Inside Building B Vent room directly to t...

Страница 8: ... qualified chimney cleaner Creosote will ignite if highly heated Adirtychimneyfluemay createanddistributesootwithin the house Inspect chimney and firebox flue for damage If dam aged repair flue and firebox before operating heater WARNING Seal any fresh air vents or ash clean out doors located on floor or wall of fire place If not drafting may cause pilot outage or sooting Use a heat resistant seal...

Страница 9: ...ane LP gas but not both Gas type is indicated on the rating plate Field conversion is not permitted INSTALLATION AND CLEARANCES For Vent Free Operation WARNING Maintain the minimum clearances If you can provide greater clearances from floor ceiling and adjoining wall Installation Continued Carefully follow the instructions below This will ensure safe installation into a masonry UL127 listed manufa...

Страница 10: ... if noncombustible mate rial is more than 12 you may need the hood accessory to deflect heat away from your mantel shelf See Figure 5 and Figures 6 and 7 page 9 for minimum clearances IMPORTANT If you cannot meet these mini mum clearances you must operate heater with chimney flue damper open Go to Install ing Damper Clamp Accessory for Vented Operation page 12 Heat Resistant Material A Figure 5 He...

Страница 11: ...vel Figure 7 Minimum Mantel Clearances When Using Hood Floor Clearances A If installing appliance on the floor level you must maintain the minimum distance of 14 to combustibles see Figure 8 B If combustible materials are less than 14 to the fireplace you must install appliance at least 5 above the combustible flooring see Figure 9 Hearth 5 Min Combustible Material Figure 9 Minimum Fireplace Clear...

Страница 12: ...ent flue open ing you must provide Attach damper clamp so the minimum permanent flue opening will be maintained at all times Area of Various Standard Round Flues Diameter Area 5 20 sq inches 6 29 sq inches 7 39 sq inches 8 51 sq inches Chimney Height Minimum Permanent Flue Opening 6 to 15 39 sq inches 15 to 30 29 sq inches Damper Damper Clamp Damper Damper Clamp Damper Figure 10 Attaching Damper C...

Страница 13: ...mustconnectheatertogas supply Follow all local codes CAUTION Never connect propane LP fireplace directly to the propane LP supply This heaterrequiresanexternalregu lator not supplied Install the external regulator between the heater and propane LP supply WARNING Never connect natural gas fireplace to private non utility gas wells This gas is commonly known as wellhead gas Installation Items Needed...

Страница 14: ...reach for cleaning Install in piping system between fuel supply and heater Locate sediment trap where trapped matter is not likely to freeze A sediment trap traps moisture and contaminants This keeps them from going into heater controls If sediment trap is not installed or is installed wrong heater may not run properly CAUTION Avoid damage to regulator Hold gas regulator with wrench when connectin...

Страница 15: ...stem by either opening propane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air Figure 15 Equipment Shutoff Valve Open Closed Equipment Shutoff Valve Installation Continued Figure 16 Checking Gas Joints Propane LP Only Gas Valve Location Propane LP Supply Tank Equipment Shutoff Valve Gas Meter Figure 17 Checking ...

Страница 16: ...t sit flat on the black sheet metal and behind the left metal tab as shown in Figure 19 3 Place front left and right logs and rear log as shown in Figure 20 4 Place top left log as shown in Figure 21 page 17 The bottom of the log is shaped to fit onto the recessed areas of the front left log and the rear log The recessed areas are painted yellow 5 Place top right log as shown in Figure 21 page 17 ...

Страница 17: ...will not push in or turn by hand don t try to repair it call a quali fied service technician or gas supplier Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water ligh...

Страница 18: ...shutoff valve is fully open 3 Press in and turn control knob clockwise to the OFF position 4 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information page 17 If you don t smell gas go to the next step 5 Press in control knob and turn counter clockwise to the PILOT position Keep control knob pressed in for five 5 s...

Страница 19: ...a correct pilot flame pattern Figure 26 shows an incorrect pilot flame pat tern The incorrect pilot flame is not touching the thermocouple This will cause the thermo couple to cool When the thermocouple cools the heater will shut down If pilot flame pattern is incorrect as shown in Figure 26 turn heater off see To Turn Off Gas to Appliance see Troubleshooting page 21 Note The pilot flame on natura...

Страница 20: ...and let cool Remove blockage blocked burner flame holes will create soot WARNING Turn off heater and let cool before cleaning CAUTION You must keep control areas burners and circulating air passageways of heater clean Inspect these areas of heater before each use Have heater inspected yearly by a qualified service person Heater may need more frequent cleaning due to excessive lint fromcarpeting pe...

Страница 21: ... in PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Replace ignitor cable 4 Replace ignitor 5 Replace pilot assembly 6 Replace pilot assembly 7 Install new alkaline battery in electron...

Страница 22: ...ystem to reset Repeat ignition operation 3 Fully open equipment shut off valve 4 A Contact local natural or propane LP gas company B Clean ODS pilot see Cleaning and Maintenance page 20 or replace ODS pilot assembly 5 Hand tighten until snug then tighten 1 4 turn more 6 Replace pilot assembly 7 Replace control valve 1 Contact local natural or propane LP gas company 2 Clean burner s see Cleaning an...

Страница 23: ... let warm up for a minute 2 Operate burners until air is removed from line Have gas line checked by local natural or propane LP gas company 3 Observe minimum installa tion clearances see pages 9 through 11 4 Clean burners see Clean ing and Maintenance page 20 or replace burner orifice s 1 Turn heater off when us ing furniture polish wax carpet cleaners or similar products 1 Refer to Air for Combus...

Страница 24: ...ng statement at top of page 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement at top of page 2 Control valve or gas control defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement at top of page REMEDY 1 Open window to venti late room Stop using odor causing products while heater is running...

Страница 25: ... only original replacement parts This will protect your warranty coverage for parts replaced under warranty Contact authorized dealers of this product If they can t supply original replacement part s call FMI PRODUCTS LLC at 1 866 328 4537 When calling have ready your name your address model and serial numbers of your heater how heater was malfunctioning type of gas used propane LP or natural gas ...

Страница 26: ... com 125010 01A 26 Parts Models VULC18NV VULC18PV VULC24NV VULC24PV VULC30NV VULC30PV ezc18n ezc18p ezc24n ezc24p ezc30n and ezc30p LPG 5 6 21 14 22 14 23 26 24 2 2 19 20 16 1 18 17 10 11 4 3 8 8 12 14 13 7 15 9 8 25 ...

Страница 27: ...7934 01 Inlet Tube 1 117934 02 Inlet Tube 1 16 099387 08 Pilot Tube 1 17 098508 01 Valve Retainer Nut 1 18 119583 05 Control Valve Natural 1 119583 06 Control Valve Propane LP 1 19 098325 01 Roll Pin 1 20 098462 03 Control Rod 1 21 098354 01 Control Knob 1 22 119676 01 Valve Bracket 1 23 117944 01 Manual Valve Bracket 1 24 117943 01 Control Rod Bracket 1 25 098276 01 Plug 1 8 NPTF Hex Head 1 26 M1...

Страница 28: ...ART NUMBER DESCRIPTION QTY VULC18 EZC18 VULC24 EZC24 VULC30 EZC30 1 125055 13 125055 02 125055 08 Front Right Log 1 2 125055 12 125055 01 125055 07 Front Left Log 1 3 125055 15 125055 04 125055 10 Middle Right Log 1 4 125055 16 125055 05 125055 11 Middle Left Log 1 5 125056 01 125056 02 125056 02 Ramp Log 1 6 125055 14 125055 03 125055 09 Rear Log 1 7 125055 06 125055 06 125055 06 Top Log 1 6 5 1 ...

Страница 29: ...DAMPER CLAMP GA6080 For all models Permanently opens chimney flue damper for vented operation LAVA ROCK GA6060 For all models Order when additional rock is desired Purchase these heater accessories from your local dealer If they can not supply these accessories call FMI PRODUCTS LLC at 1 866 328 4537 for referral information You can also write to the address listed on the back page of this manual ...

Страница 30: ..._____________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________...

Страница 31: ..._____________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________...

Страница 32: ...is product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic material labor and incidental costs associated with warranty repairs unless expressly covered by this warranty are not reimbursable under this warranty and are the responsibility of the owner Excluded ...

Отзывы: