www.fmiproducts.com
119315-01D
6
Screen
Shoulder
Screw
Figure 3 - Assembling Hood
Figure 2 - Removing and Replacing
Screen
aiR FoR CoMBUsTioN
aND VENTilaTioN
WARNING: This fireplace
shall not be installed in a con
-
fined space or unusually tight
construction unless provisions
are provided for adequate com
-
bustion and ventilation air. Read
the following instructions to in
-
sure proper fresh air for this and
other fuel-burning appliances in
your home.
Today’s homes are built more energy efficient
than ever. New materials, increased insulation
and new construction methods help reduce
heat loss in homes. Home owners weather
strip and caulk around windows and doors
to keep the cold air out and the warm air in.
During heating months, home owners want
their homes as airtight as possible.
While it is good to make your home energy
efficient, your home needs to breathe. Fresh
air must enter your home. All fuel-burning ap-
pliances need fresh air for proper combustion
and ventilation.
Exhaust fans, fireplaces, clothes dryers and
fuel burning appliances draw air from the
house to operate. You must provide adequate
fresh air for these appliances. This will insure
proper venting of vented fuel-burning appli-
ances.
PROVIDING ADEQUATE
VENTILATION
The following are excerpts from N
ational Fuel
Gas Code. ANSI Z223.1/NFPA 54, Section
5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three
following ventilation classifications:
1. Unusually Tight Construction
2. Unconfined Space
3. Confined Space
The information on pages 6 through 8 will help
you classify your space and provide adequate
ventilation.
4. Check installation of brick liners. Brick
liners are in four pieces: 2 sides, 1 back
and 1 top.
5. Place hood under top edge of firebox
opening. Use 3 screws from hardware kit
to mount hood to firebox (see Figure 3).
assEMBly
Continued
Hood
Screw
Top Trim
Panel