![FMC Technologies Sening EPE2 Скачать руководство пользователя страница 33](http://html.mh-extra.com/html/fmc-technologies/sening-epe2/sening-epe2_installation-manual_2312620033.webp)
Sening
®
Innovative Tank Truck Systems
EPE2-Controller for Meter Draining System
EPE2
Installation Manual
MN F08 003 US /
DOK-450E
Rev. 1.03 / JS / jp / March 2010
33
6 EPE2-Controller Technical data
Power supply unit:
Type: SVC-2S
Input voltage 15V – 28V /1A
Outputs(static): 12V DC, max total current 430 mA
Outputs (frequency):
12V AC, f = 100Hz
when connecting solenoid valves,
rated current consumption < 400mA per solenoid valve
Working temperature: T
amb
-20
°
C to +55
°
C
Control unit:
Type: REC-1S
Input circuit: Connection of sensors as per Namur / level sensor Type NS2
Working temperature: T
amb
-20
°
C to +55
°
C
Содержание Sening EPE2
Страница 42: ...42 Rev 1 03 JS jp März 2010 MN F08 003 US DOK 450E Drawings E51 351677 Control unit residue discharge REC 1 ...
Страница 45: ...MN F08 003 US DOK 450E Rev 1 03 JS jp März 2010 45 Approvals EC Declaration of Conformity ...
Страница 46: ...46 Rev 1 03 JS jp März 2010 MN F08 003 US DOK 450E ...