![FMC Technologies Sening EPE2 Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/fmc-technologies/sening-epe2/sening-epe2_installation-manual_2312620016.webp)
EPE2-Controller for Meter Draining System
EPE2
Installation Manual
Sening
®
Innovative Tank Truck Systems
16
Rev. 1.03 / JS / jp / March 2010
MN F08 003 US /
DOK-450E
3.3
Switching outputs for “MultiFlow residue discharge“ operation
During operation of „
MultiFlow residue discharge
“ none of the
EPE2
outputs are switched. The
switching information is transferred via the CAN Bus to the MultiFlow, which then takes over the
control.
When setting the “
MultiFlow residue discharge
“ the DIP switch S1-2 on the
power supply board
SVC-2S
always has to be set into the “
ON
“ position. Hence
other optional devices can be powered by the flow computer 24V (out) connec-
tion.
3.4
Setting the sensor type
The
EPE2
-Controller supports 3 types of sensors. The selected switch or sensor is connected to
the
J3
input on the
REC-1S
control board.
The setting has to be made before commissioning via the jumpers
Jp4
and
Jp5
on the
REC-1S
printed circuit board, listed in the following table.
The 3 sensor types have to be supplied with different voltages. This adjustment is made with the
two jumpers as displayed in the table:
Sensor type
Short circuit
interruption detec-
tion
Jumper
Jp4
Jumper
Jp5
Parame-
ter 2
(via PC or
Laptop)
**
*
1
Sensor with Namur output
YES
2-3
inserted
1
◄
2
optoelectronic sensors (NS2)
YES
1-2
removed
2
3
mechanical switch
NO
1-2
inserted
3
*
: Factory or reset settings.
Table 2: Sensor type settings
The proximity switches are Namur set in the factory.