![FMC Technologies Sening EPE2 Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/fmc-technologies/sening-epe2/sening-epe2_installation-manual_2312620013.webp)
Sening
®
Innovative Tank Truck Systems
EPE2-Controller for Meter Draining System
EPE2
Installation Manual
MN F08 003 US /
DOK-450E
Rev. 1.03 / JS / jp / March 2010
13
3 Commissioning
The
EPE2-
Controller is factory set so that no adjustments are required rafter installation. Just the
operating mode, switching logic and the sensor type have to be checked and adapted if necessary.
3.1
Adaptation of the operating mode
•
A difference is made between the
“Stand-Alone residue discharge“
and
“MultiFlow residue
discharge“
.
•
Both operating modes as well as other settings are made via the DIP switch S1 on the
REC-1S
printed circuit board (see also Figure 6 / page 18).
The DIP switch
S1
settings are shown in the following table.
DIP
switch
S1
on the
REC-1S
board
MultiFlow residue discharge
(from MID version 5.00)
1 = ON – With MultiFlow
2 = OFF – No Test
3 = ON – Only channel 2
4 = OFF – Reserved
5 = ON |
6 = OFF | CAN-Bus
7 = ON | address =
5
8 = OFF |
DIP
switch
S1
on the
REC-1S
board
Stand-Alone
1 = OFF – Stand-Alone
2 = OFF – No Test
3 = ON – Only channel 2
4 = OFF – Reserved
5 = x
|
6 = x
| CAN-Bus
7 = x
| address = xx
8 = x
|
Table 1: DIP switch S1 settings