![FMC Technologies Sening EPE2 Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/fmc-technologies/sening-epe2/sening-epe2_installation-manual_2312620019.webp)
Sening
®
Innovative Tank Truck Systems
EPE2-Controller for Meter Draining System
EPE2
Installation Manual
MN F08 003 US /
DOK-450E
Rev. 1.03 / JS / jp / March 2010
19
3.7
Parameters in MultiFflow
No.
Name
Seal
K Factory
Setting
Meaning
3.1.6.8
EPE2
(from version 5.00)
3.1.6.8.1
Use of EPE2
M
2 0 (no)
Activation of EPE2 required for optional
residue discharge
3.1.6.8.2
EPE2 node
M
2 5
Node number of EPE2 when activated
3.1.6.8.3
EPE2 interval
M
2 600ms
EPE2 request interval. Used to trigger
EPE2 inactivity monitor.
3.1.8.5
Draining
3.1.8.5.1
Drain control
M
2 0 (no)
(up to version 5.00)
Activates an instruction for residue removal
in the event of product change.
3.1.8.5.2
Receipt draining
M
2 0 (no)
(up to version 5.00)
Parameter currently not in use. In a future
program version will activate printout of a
receipt after residue removal.
3.1.8.5.1
Residue removal
control
M
2 1
(from version 5.00)
1 : Off
2: Stand-alone
Activates an instruction for residue removal
in the event of product change.
3: EPE2 manual
As 2, however the wet leg sensor con-
nected to the EPE2 monitors the residue
removal. No restart of MultiFlow required
after residue removal.
4: EPE2 automatic
As 3, however "Autom. residue removal"
menu item (menu 8) includes the option to
control a pump for the measuring system
residue removal via the EPE2 output.
3.1.8.5.2
Residue removal
timeout
M
2 0 (no)
(from version 5.00)
Timeout for the autom. draining of the
measuring system with the aid of the EPE2
in "EPE2 automatic" mode. Residue re-
moval stops automatically after this period.
3.1.8.5.3
Residue removal
receipt
M
2 0 (no)
(from version 5.00)
Parameter currently not in use. In a future
program version will activate printout of a
receipt after residue removal.