Wiring, Large Pumps, SubCab 12–lead Sensor Cable
Wire
Connection
This table shows the connection of the wires for a SubCab 12-lead sensor cable:
Sensor/Component
Sensor cable, no.
Base unit terminal
block, no.
1
13
FLS — Leakage in stator housing
1)
2
14
3
8
Pt100 — Temperature measurement,
main bearing
4
4
5
1
Thermal switches — Temperature
guard stator windings
6
2
7
15
FLS — Leakage in junction box
1)
(2)
(14)
8
3
Pt100 — Temperature measurement,
stator winding ph 1
(4)
(4)
Pump memory:
• RS–485 B
2)
9
38
• RS-485 A
2)
10
37
• Supply, ground
11
36
• Supply, 12V +
12
35
(Screen)
If applicable, attach
screen to ground
terminals in the
• pump top
and
• electrical cabinet.
NOTE!
1)
FLS means either of leakage sensors FLS/FLS10/FLS20/FLS30 depending on type
of pump.
2)
Communication port 37-38 for RS-485 is common to both pump memory and
operator panel.