Read Operational Data
Read Operational Data
Available Functions
Functions that may be available are described below. Whether a function is available or
not, depends on previous installation and configuration.
Menus to use
Menu name
No.
Description
Comment
Value
can be
reset?
Level
2_
Sump level
No
P1 current – P4 current 3_– 6_
Current for Pump 1–4.
No
P1 start counter
7_1
Total number of starts for
pump 1.
Yes
P1 run hour
7_2
Total runtime for pump 1.
Yes
..
..
P4 run hour
7_8
Total runtime for pump 4.
Yes
Overflow flow
8_16
Estimated overflow flow.
No
Overflow volume
8_17
Estimated overflow
volume.
Yes
Overflow count
8_18
Number of overflows
Yes
No. of major overfl.
8_19
Number of major
overflows
An overflow is also a major overflow
when no other overflow has
occurred for the last 24 hours.
Yes
Overflow time
8_20
Total overflow time
Yes
Rain
9_
Daily rain value
No
Free flow
10_1
Estimated free flow.
The free flow is also called the
inflow, and is the flow into the
sump.
No
Pumped volume
10_2
Estimated volume
pumped away from sump.
Yes
Sump volume
10_3
Estimated volume
remaining in sump.
Yes
Calc. capacity P1 – P4
12_1 –
12_4
Capacity for Pump 1–4.
No
Reset operational data
1. View the relevant operation menu.
Example: P1 start counter menu.
2. Press OK.
Result: Menu window shows "Reset value? No".
Read Operational Data
36
APP 541 User manual