![Flux F 424 HC Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/flux/f-424-hc/f-424-hc_original-main-operating-instructions_2310940039.webp)
Main Operating Instructions for Barrel and Container Pumps
39 / 60
ENGLISH
8
Maintenance
To perform maintenance on the pump, the motor must be removed from the pump.
All motors must be checked regularly in accordance with the legal/country-specific
requirements and accident prevention regulations (in Germany, e.g. BGV A3).
Check the motor, mains cable, pump and hose regularly for operating safety.
8.1
Dismantling and Disposal
>
The pump, the hose and the fittings must be emptied prior to dismantling.
>
Collect environmentally harmful substances and liquids in appropriate containers and
dispose of them in an environmentally sound manner.
>
Dispose of scrap material and parts that cannot be repaired or reused in an environ-
mentally sound manner.
Danger from splashing liquids!
Before removing the motor:
•
Empty pump, hose and fittings.
•
Check the hose clamps or hose holders regularly for firm seating.
•
Do not remove the motor as long as there is still back-pressure within the
system.
•
With pressurised containers, the motor must only be taken off when the con-
tainer is depressurised.
Danger of electric shock!
•
Dirt, high humidity or material damage to the motor housing may lead to
dangerous electric shocks.
•
Only start three-phase motors with an upstream motor protection switch
installed.
•
Installation work on three-phase motors may only be carried out by qualified
personnel.
•
Check the mains connection cable for damage before every use.
•
Changes to the mains connection may only be carried out by qualified elec-
tricians.
Attention! Material damage!
•
Avoid dry running.
Note
•
Always replace defective parts.
•
Only use genuine spare parts.
•
When returning the pump for repair, it must be accompanied by the decon-
tamination certificate (download at www.flux-pumpen.de).
Содержание F 424 HC
Страница 21: ...Allgemeine Betriebsanleitung Fass und Beh lterpumpen 21 60 DEUTSCH 9 Anhang 9 1 Konformit tserkl rung...
Страница 40: ...40 60 Main Operating Instructions for Barrel and Container Pumps ENGLISH 9 Annex 9 1 Declaration of Conformity...
Страница 59: ...Notice d instructions g n rale Pompes vide f ts 59 60 FRAN AIS 9 Annexe 9 1 D claration de Conformit...
Страница 60: ...FB 98000001_00 010 10 DEF FB 98000001_01 0211 10 DEF...