Speaker
The TS25D Test Set’s speaker allows hands-free
listening in both Talk and Monitor Mode. Pressing the
SPKR
key will turn the speaker on. Pressing the
SPKR
key again will increase the speaker’s volume. Pressing
the
SPKR
key a third time will turn the speaker off.
On the standard TS25D Test Set, the speaker turns off
when you switch between Monitor and Talk modes. If
you turn off the test set while the speaker is on, the
speaker will be off next time you turn on the test set.
On the TS25D CO Test Set, the speaker stays on when
you switch between Monitor and Talk modes. If you
turn off the test set while the speaker is on, the speaker
will be on next time you turn on the test set.
Caution
Be sure the test set is not near your ear
when you turn on the speaker, as the
volume can be quite loud.
Belt Clip
An optional battery door with a belt clip is available for
the standard TS25D Test Set. For information on
availability of the optional belt clip, contact your local
Fluke Networks distributor.
The TDS25D CO Test Set has a belt clip on the battery
door.
Line Cord
See Figure 1.
The test set is equipped with a field replaceable line
cord. The line cord is attached to the test set at the
transmitter end of the test set.
The line cord included with the standard TS25D Test Set
has angled bed-of-nails clips. The line cord included
with the TS25D CO Test Set has a 346A plug. Extension
line cords for the 346A plug are sold separately.
For information on availability of line cords, contact
your local Fluke Networks authorized distributor.
Battery
The battery compartment is on the back of the tester.
See “Replacing the Battery” on page 16.
Note
If the test set fails to operate properly at any
time, first replace the battery and retest before
sending the test set in for repair.
A 9 V alkaline battery must be installed for the test set
to operate. Do not use rechargeable batteries.
When the battery icon shows a low battery, the battery
has anywhere from a few hours to several days of life
remaining depending on how the test set is used. The
battery will be used up much faster if the Talk Battery
function or the speaker is used.
If the test set ever stops working, replace the battery. If
it still doesn’t work, contact Fluke Networks Technical
Support.
Headset
On the TS25D Test Set, an audio jack is available for the
connection of a headset. The 3.5 mm jack is located on
the side of test set. The TS25D Kit (Model 25501109)
comes with a headset.
For information on availability of additional headsets
or replacement headsets, contact your local Fluke
Networks authorized distributor.