background image

11

Call and Dialing Functions

Answering a Call

To answer an incoming call:

1

Place the test set in Monitor mode to respond to 
incoming ringing signals.

2

If a ringing signal is received, set the slide switch to 
the Talk (

T

) position. The test set automatically 

tests for high-speed data on the line.

3

If no data is detected, the test set will go off hook.

4

If data is detected, test set will lock out and display 
the message

 DATA DETECTED, DOWN ARROW TO 

OVERRIDE

.

5

To go off hook with data present you can override 
the data lockout (see Data Lockout Override).

Disconnecting a Call

To disconnect a call, switch the test set off, or to 
Monitor, or remove the clip leads from the line.

Last Number Redial

If a call is not successful and you wish to redial the same 
number, do the following: 

1

Switch the test set off, then set the slide switch to 
the Talk (

T

) position.

2

After the test set goes off-hook press the 

LNR

 key. 

The last number dialed will be automatically 
redialed. 

The last number redial function is available in either 
the Pulse or Tone Mode. The method of dialing is not 
stored with the number. The redial memory has a 23-
digit capacity. 

In Tone Dialing mode, the dialing keys that are 
permitted to be stored in LNR memory include 
1,2,3,4,5,6, 7,8,9,0,

, and #. If the asterisk (

) and 

pound (#) keys are pressed in Pulse mode they will be 
ignored.

Memory Dialing

The TS25D Test Set allows the user to dial pre-
programmed numbers in either Tone or Pulse mode. If 
dialing in Pulse mode and the stored number contains 
an asterisk (

) or pound (#) symbol, the digits will be 

ignored.

To activate Memory Dialing:

1

Connect the test set to a working telephone line 
and go off-hook by setting the slide switch to the 
Talk (

T

) position.

2

Press the 

SEL

 key. The Main menu is displayed.

3

At the Main menu, highlight 

CALL PHONEBOOK

 

with the arrow keys, then press the 

SEL

 key. The 

list of phonebook entries is displayed. Pressing the 
arrow keys lets you scroll through all locations (0 
through 9). The small number in the upper right of 
the LCD tells you which memory location you have 
selected.

4

Select the desired phonebook entry with the 
arrow keys, then press 

SEL

 key, or enter a number 

(0 through 9) on the keypad. The number is 
automatically dialed.

Speed Dialing (TS25D CO)

With the TS25D CO Test Set, you can dial numbers from 
memory as described above, or you can use the speed 
dialing feature, as follows:

1

Connect the TS25D CO Test Set to the telephone 
line.

2

Set the slide switch to the Talk (

T

) position, and 

listen for a dial tone.

3

Once you hear dial tone, press the 

BACK

 key 

followed by the number of the memory location 
(0 through 9) containing the telephone number 
you want to dial. 

The telephone number in the selected memory 
location will be automatically dialed.

Содержание TS 25D

Страница 1: ...TS 25D Test Set PN 2451820 October 2005 Rev 3 3 13 2005 2009 2012 2013 Fluke Corporation All rights reserved Printed in China All product names are trademarks of their respective companies Users Guide...

Страница 2: ...or replacement of a defective product which is returned to a Fluke Networks authorized service center within the warranty period To obtain warranty service contact your nearest Fluke Networks authori...

Страница 3: ...des and Functions 6 Monitor Mode 6 Talk Mode 6 Data Lockout 6 Data Lockout Override 7 High Voltage Lockout 7 Low Voltage Lockout 8 Talk Battery 8 Caller ID Call Waiting ID 9 Toner 9 DTMF Detection 10...

Страница 4: ...Pause Duration 14 Flash Duration 14 System Timeout 15 Speaker Timeout 15 Data Lockout 15 Firmware Version 15 Factory Settings 16 Maintenance 16 Keypad Care 16 Replacing the Battery 16 Replacing the L...

Страница 5: ...ccess to valuable information on product updates troubleshooting tips and other support services To register fill out the online registration form on the Fluke Networks website at www flukenetworks co...

Страница 6: ...Flash Memory Dialing Tone and Pulse Dialing Displays Voltage when on hook Displays Current when off hook Polarity Indication Detect and Display Caller ID Call Waiting ID CIDCW Toner Talk Battery DTMF...

Страница 7: ...ric keypad is used to dial telephone numbers and make function selections The keypad includes 12 standard dialing keys the asterisk key and pound key SPKR The SPKR speaker key turns the speaker on inc...

Страница 8: ...of the test set The line cord included with the standard TS25D Test Set has angled bed of nails clips The line cord included with the TS25D CO Test Set has a 346A plug Extension line cords for the 346...

Страница 9: ...the line is not powered Battery The battery icon indicates the battery s charge level The battery level is continuously displayed in Monitor and Talk mode On off hook The telephone icon tells you if...

Страница 10: ...e test set will go off hook and draw dial tone An off hook TS25D test Set works like a standard telephone When off hook the test set is used to perform its main purpose which is to verify the proper o...

Страница 11: ...ARROW TO OVERRIDE Now if you want to go off hook to access the analog phone service sharing the line with ADSL press the down arrow as instructed on the LCD The test set will override the lockout wil...

Страница 12: ...oned When the test set connected to a line carrying data signals but no DC voltage is switched to Talk mode the LCD will display DATA DETECTED AND LOW VOLT LOCKOUT Some data services have no associate...

Страница 13: ...or arrange for someone to call the line the test set is connected to When the call comes in you will hear the Call Waiting Alert tone This will be followed by the CAS tone and the Caller ID message W...

Страница 14: ...ck to Monitor mode DTMF detection is only available when the TS25D Test Set is in Monitor mode Call and Dialing Functions Note Remove the protective film that covers the LCD display before using your...

Страница 15: ...erisk and pound keys are pressed in Pulse mode they will be ignored Memory Dialing The TS25D Test Set allows the user to dial pre programmed numbers in either Tone or Pulse mode If dialing in Pulse mo...

Страница 16: ...slash quote period or 1 depending on how many times you press the key Use the Up arrow to erase characters In this case the Up arrow moves the cursor to the left 7 After the entry is complete press th...

Страница 17: ...rsor location A comma is used to represent a pause Pauses are used to put time delays into a string of numbers The default pause duration is 4 seconds 10 After the entry is complete press the SEL key...

Страница 18: ...screen see Figure 2 Timing Use the Timing option to set the Pause duration and the Flash duration Pause Duration To set the Pause duration 1 Set the slide switch to the Talk T or Monitor M position 2...

Страница 19: ...ss the SEL key or press 3 on the keypad 3 Press 2 SPKR TIMEOUT 4 Highlight the desired time with the arrow keys then press the SEL key or press one of the following keys on the keypad 1 2 minutes TS25...

Страница 20: ...imilar chlorinated solvent on the test set Doing so will damage the test set If moisture should get inside the test set let the test set dry at normal room temperature for 24 hours DO NOT HEAT THE TES...

Страница 21: ...r 5 Loosen the two screws that hold the line cords to the PCB 6 Using needle nose pliers or one of the line cord clips remove the two screws and washers from the line cord connectors 7 Position the sc...

Страница 22: ...last number redial memory Digit Capacity 23 digits per memory Pause Duration User programmable Default 4 seconds Hook Flash Duration User programmable Default 600 ms Automatic Speaker Shut Off Durati...

Отзывы: