OF-500 OptiFiber Certifying OTDR
Technical Reference Handbook
2-22
Fiber ID Options
You can create or select fiber IDs as follows:
•
You can create an ID after you press
s
. You can
also highlight a used or unused ID in a list; then press
t
to edit it into a new ID. The next time you press
s
, the tester increments the last character of the ID
you created (the auto increment feature).
•
You can create a list of sequential fiber IDs by
configuring a template on the Job tab in Setup. Select
the IDs from the AUTO SEQ IDs list after you press
s
.
•
You can create ID lists in LinkWare software; then
download them to the tester. Select the IDs from the
DOWNLOAD IDs list after you press
s
.
•
After you press
s
, you can use an ID already
assigned to a record stored in the current folder. This
lets you overwrite existing results or add new results to
an existing record. Select the ID from the IDs IN
CURRENT FOLDER list after you press
s
.
Using the Auto Increment Feature
The auto increment feature increments the last
alphanumeric character in the fiber ID you enter. For
example, if you save a test with the ID “A0”, the tester
increments the ID to “A1” the next time you save a test. As
you save more tests, the ID increments from “A1” through
“A9”; then back to “A0”. Consecutive digits increment from
right to left, but other characters do not.
To use this feature, do the following:
1
Run a test; then press
s
.
2
Enter a fiber ID in the SAVE RESULT IN FIBER ID: box.
You may need to press
A
Edit ID to see this box.
3
Press
s
again.
4
The next time you press
s
, the incremented fiber
ID appears in the editing box. Press
s
again to use
the ID.
Содержание OF-500-01 OptiFiber
Страница 4: ......
Страница 18: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook xiv...
Страница 29: ...Getting Acquainted Powering the Tester 1 9 1 ajt20f eps Figure 1 1 Battery Pack Feature...
Страница 31: ...Getting Acquainted Verifying Operation 1 11 1 ajt56f eps Figure 1 2 Removing the Module...
Страница 48: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 1 28...
Страница 76: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 2 28...
Страница 95: ...Using the OTDR Running the OTDR Test 3 19 3 ajt33f eps Figure 3 12 Connecting the OTDR to Spooled Cable...
Страница 110: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 3 34...
Страница 117: ...Using the OTDR Comparing OTDR Traces 3 41 3 ajt68f eps Figure 3 16 Comparing OTDR Traces F G H C D E A B...
Страница 132: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 3 56...
Страница 135: ...Using the ChannelMap Function Running the Test 4 3 4 ajt55f eps Figure 4 2 ChannelMap Test Connections...
Страница 138: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 4 6...
Страница 141: ...Using the FaultMap Function Running the Test 5 3 5 ajt55f eps Figure 5 2 FaultMap Test Connections Channel to be tested...
Страница 144: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 5 6...
Страница 155: ...Using the Loss Length Option Changing the Connector Adapter 7 3 7 ajt61f eps Figure 7 2 Changing the Connector Adapter...
Страница 196: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 7 44...
Страница 200: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 8 4 ajt03f eps Figure 8 2 Using the Visual Fault Locator...
Страница 216: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 10 10...
Страница 254: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 12 30...
Страница 256: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook A 2...
Страница 259: ...Loss Test Methods 1 Jumper Method B 3 B ajt59f eps Figure B 1 1 Jumper Reference and Test Connections singlemode shown...
Страница 261: ...Loss Test Methods 2 Jumper Method B 5 B ajt58f eps Figure B 2 2 Jumper Reference and Test Connections singlemode shown...
Страница 268: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook C 2...
Страница 278: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 10 OTDR 3 11 WEAK SIGNAL 3 35 Z TEST METHOD B 8 zoom 3 27...