OF-500 OptiFiber Certifying OTDR
Technical Reference Handbook
3-40
Figure 3-15. OTDR Functions Menu
ajt69f.eps
C
New Comparison Trace from Memory: Lets you
select a new trace from memory to compare to the
reference trace.
D
Turn Off Trace Overlay: Removes the reference trace
from the OTDR plot.
E
Reference Trace/Comparison Trace: The traces and
wavelengths currently selected for the trace overlay
function. To select or deselect a wavelength,
highlight a trace name; then press
t
.
F
OTDR PLOT GRID: Turns the OTDR plot grid on and
off.
G
MARKER DELTA MODE: Sets the mode for the
measurement cursors on the OTDR plot:
•
Δ
distance
Δ
dB: The cursor readout shows the
difference in the power levels (in decibels)
between the cursors.
•
dB per unit distance: The cursor readout shows
the power loss (in decibels) that would occur
over 1 km or 1 kft of cable based on the loss
between the cursors.
A
New Reference Trace: Turns on the trace overlay function.
Lets you select a new reference trace from memory.
B
Measure New Comparison Trace: Runs the OTDR test to get a
new trace to compare to the reference trace.
A
B
C
D
F
G
E
Содержание OF-500-01 OptiFiber
Страница 4: ......
Страница 18: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook xiv...
Страница 29: ...Getting Acquainted Powering the Tester 1 9 1 ajt20f eps Figure 1 1 Battery Pack Feature...
Страница 31: ...Getting Acquainted Verifying Operation 1 11 1 ajt56f eps Figure 1 2 Removing the Module...
Страница 48: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 1 28...
Страница 76: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 2 28...
Страница 95: ...Using the OTDR Running the OTDR Test 3 19 3 ajt33f eps Figure 3 12 Connecting the OTDR to Spooled Cable...
Страница 110: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 3 34...
Страница 117: ...Using the OTDR Comparing OTDR Traces 3 41 3 ajt68f eps Figure 3 16 Comparing OTDR Traces F G H C D E A B...
Страница 132: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 3 56...
Страница 135: ...Using the ChannelMap Function Running the Test 4 3 4 ajt55f eps Figure 4 2 ChannelMap Test Connections...
Страница 138: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 4 6...
Страница 141: ...Using the FaultMap Function Running the Test 5 3 5 ajt55f eps Figure 5 2 FaultMap Test Connections Channel to be tested...
Страница 144: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 5 6...
Страница 155: ...Using the Loss Length Option Changing the Connector Adapter 7 3 7 ajt61f eps Figure 7 2 Changing the Connector Adapter...
Страница 196: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 7 44...
Страница 200: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 8 4 ajt03f eps Figure 8 2 Using the Visual Fault Locator...
Страница 216: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 10 10...
Страница 254: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 12 30...
Страница 256: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook A 2...
Страница 259: ...Loss Test Methods 1 Jumper Method B 3 B ajt59f eps Figure B 1 1 Jumper Reference and Test Connections singlemode shown...
Страница 261: ...Loss Test Methods 2 Jumper Method B 5 B ajt58f eps Figure B 2 2 Jumper Reference and Test Connections singlemode shown...
Страница 268: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook C 2...
Страница 278: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 10 OTDR 3 11 WEAK SIGNAL 3 35 Z TEST METHOD B 8 zoom 3 27...