Specifications
45
Performance Specifications
Cable types tested
Twisted pair:
UTP, FTP, SSTP
Coaxial
: 75
, 50
, 93
Length test
Range
: 460 m (1500 ft)
Resolution
: 0.3 m (1 ft)
Typical accuracy
:
4% or 0.6 m (2 ft) whichever is greater. NVP uncertainty is an additional
error.
Calibration
: User-settable NVP for twisted pair and coax. Can determine actual NVP with
known length of cable.
Wiremap test
Detects single-wire faults, shorts, miswires, split pairs, and up to seven far-end adapter IDs.
The wiremap is drawn with proportional length to visually indicate the approximate location
of faults.
Port detection
Detects the advertised speed of 802.3 Ethernet ports.
Tone generator
Supports toning and cable mapping with a Fluke Networks digital IntelliTone
™
probe.
Generates four tones compatible with typical analog probes.
SmartTone
™
feature gives positive identification of cables in bundles when using an
IntelliTone or an analog probe.