Local Operation
Rear-Panel Controls and Connectors
3
3-21
Rear-Panel Controls and Connectors
Figure 3-4 shows the rear panel of the Instrument and identifies each of its controls and
connectors. Functional and operational descriptions for each of the controls and
connectors are given in the following paragraphs.
CA L
IEEE-488
SH1 AH1 T6
L4 SR1
RL1 PP0 DC1 DT0 C0 E2
MADE IN UK
FLUKE CORPORA
TION
www .f
luk
e.com
TO BE
APPLIED FOR
CONFORMS TO UL STD. UL61010A-1
.
CERTIFIED
TO CAN/CSA STD. C22.2 No
.1010.1
-92
SAFETY W
ARNING
NO TE
DISCONNECT PO
WER AND SIGNAL LEADS
BEFORE REMO
VING CO
VERS.
FOR CONTINUED PR
O TECTION
AG AINST ELECTRIC SHOCK
THE POWER CORD PR
O TECTIVE CONDUCT
OR MUS
T BE
CONNECTED TO SAFETY EAR
TH ( GR
OUND ).
FOR CONTINUED PR
O TECTION
AG AINST FIRE
USE 250V FUSE OF CORRECT RA
TING.
READ OPERA
TORS MANUAL BEFORE USE.
NO USER SER
VICEABLE P
AR TS CONT
AINED, DO NO
T
REMO VE CO
VERS, HAZARDOUS
VOLTAGES PRESENT
.
REFER SER
VICE
TO QUALIFIED PERSONNEL.
PO WER INPUT
230
VA MAX. FREQ 47 - 63 Hz
SERIAL POR
T
FACT OR Y SET
REF FREQUENC
Y
INPUT
REF F REQUENC
Y
OUTPUT
6 7 8
ENABLE
DISABLE
1V PK INT
O
TTL INT
O
SWEEP TRIGGER
INPUT :
5V PK
AUX PRO TECTIVE
EARTH (GR
OUND)
RF COMMON
RF COMMON
5V PK
MODULA TION
LEVELLING AND
FREQUENC Y PULL
INPUT
+
_
50
5V PK
+
_
50
+
OUTPUT : TTL NOM
INTO 1k
+
1k NOM
NOM
50
10V PK MAX
Ref Frequency Output Connector
Ref Frequency Input Connector
Modulation Leveling and Frequency
Pull Input Connector
Sweep Trigger Input/Output Connector
CAL Switch
Factory Set Switch
Serial Port (Firm Ware upload)
IEEE 488 Connector
Power Block
Earth (chassis) Ground Connector
1
2
3
4
5
6
8
7
9
10
ead44f.eps
Figure 3-4. Rear Panel Controls and Connectors
Power Block and Switch
The Power Block includes the power switch and a dual fused line-power input connector
for the Instrument. Its universal design accommodates a variety of regional power cords,
line-power (90 V to 132 V and 180 V to 264 V ac), and power fuses. These various line-
power configurations and the procedures to establish them are described earlier in
Chapter 2.
IEEE 488 Connector
The Instrument includes an IEEE 488.2, SCPI (1999) Remote Interface for connecting
and controlling the Instrument remotely in a system environment. The IEEE 488
Connector provides the means for connecting a controlling system to the Instrument. The
controlling system may be as simple as a PC or as complex as an automated calibration
system.
Содержание 9640A Series
Страница 8: ......
Страница 16: ...9640A Instruction Manual viii...
Страница 22: ...9640A Instruction Manual 1 2...
Страница 40: ...9640A Instruction Manual 2 2...
Страница 108: ...9640A Instruction Manual 4A 2...
Страница 138: ...9640A Instruction Manual 4C 2...
Страница 164: ...9640A Instruction Manual 4D 2...
Страница 168: ...9640A Instruction Manual 4D 6...
Страница 170: ...9640A Instruction Manual 4E 2...
Страница 174: ...9640A Instruction Manual 4E 6...
Страница 176: ...9640A Instruction Manual 4F 2...
Страница 184: ...9640A Instruction Manual 4F 10...
Страница 186: ...9640A Instruction Manual 4G 2...
Страница 190: ...9640A Instruction Manual 4G 6...
Страница 192: ...9640A Instruction Manual 5 2...
Страница 272: ...9640A Instruction Manual 5 82...
Страница 274: ...9640A Instruction Manual 6 2...
Страница 284: ...9640A Instruction Manual 7 2...
Страница 309: ...8 1 Chapter 8 Lists of Replaceable Parts Title Page Introduction 8 3 How to Obtain Parts 8 3 Parts Lists 8 4...
Страница 310: ...9640A Instruction Manual 8 2...
Страница 316: ...9640A Instruction Manual 8 8...
Страница 320: ...9640A Instruction Manual A 4...