FW-N410-P-M_v0203_01_EN
Page 35
Preset variables
PDU
ADDRESS
REGISTER
VARIABLE
NO.
REGISTERS
R/W
TYPE
VALUE / REMARKS
d: 108
h: 0x06C
40033
unit
1
R/W uint16 0=L
1= m
3
2=US GAL
3= I GAL
4=FT3
5= BBL
6=kg
7= ton
8=US ton
9=lb
d: 33
h: 0x021
40034
decimals
1
R/W uint16
0…3
d: 214
h: 0x0D6
40215
Batch
minimum
2
R/W uint24 1...9999999
Representation: 0.000010…9999999
d: 218
h: 0x0DA
40219
Batch
maximum
2
R/W uint24 1...9999999
Representation: 0.000010…9999999
d: 200
h: 0x0C8
40201
Preset
value
2
R/W uint24 1...9999999
Representation: 0.000010…9999999
Overrun variables
PDU
ADDRESS
REGISTER
VARIABLE
NO.
REGISTERS
R/W
TYPE
VALUE / REMARKS
d: 194
h: 0x0C2
40195
Overrun
enable
1
R/W uint16 0=disable
1=enable
d: 192
h: 0x0C0
40193
Overrun
time
1
R/W uint16 1...9999
Representation: 0.0001
–
9.999 sec
Flowrate variables
PDU
ADDRESS
REGISTER
VARIABLE
NO.
REGISTERS
R/W
TYPE
VALUE / REMARKS
d: 109
h: 0x06D
40033
unit
1
R/W uint16 0=L
1= m
3
2=US GAL
3= I GAL
4=FT3
5= BBL
6=kg
7= ton
8=US ton
9=lb
d: 49
h: 0x031
40050
time unit
1
R/W uint16 0=/sec
1=/min
2=/hr
3=/day
d: 50
h: 0x032
40051
decimals
1
R/W uint16
0…3
d: 55
h: 0x037
40056
nr. of
pulses
1
R/W uint16 1...255
d: 56
h: 0x038
40057
cut-off
1
R/W uint16 1...9999
Representation: 0.1 - 999.9 seconds
Alarm variables
PDU
ADDRESS
REGISTER
VARIABLE
NO.
REGISTERS
R/W
TYPE
VALUE / REMARKS
d: 68
h: 0x044
40195
no-flow
alarm
1
R/W uint16 0=disable
1=enable
d: 46
h: 0x02E
40193
no-flow
time
1
R/W uint16 1...9999
Representation: 0.0001
–
9.999 sec
Display variables
PDU
ADDRESS
REGISTER
VARIABLE
NO.
REGISTERS
R/W
TYPE
VALUE / REMARKS
d: 195
h: 0x0C3
40196
direction
1
R/W uint16 0=decreasing 1=increasing
d: 58
h: 0x03A
40059
tank
1
R/W uint16 0=disable
1=enable
d: 67
h: 0x043
40068
backlight
1
R/W uint16 0=0%
1=20%
2=40%
3=60%
4=80%
5=100%
d: 110
h: 0x06E
40111
backlight
dimmed
1
R/W uint16 0=0%
1=20%
2=40%
3=60%
4=80%
5=100%
Flowmeter variables
PDU
ADDRESS
REGISTER
VARIABLE
NO.
REGISTERS
R/W
TYPE
VALUE / REMARKS
d: 96
h: 0x060
40097
flowmeter
signal
1
R/W uint16 0=NPN
1=NPN LP
2=Reed
3=Reed LP
4=PNP
5=PNP LP
6=NAMUR
7=coil hi
8= coil lo
9=active
d: 224
h: 0x0E0
40225
unit
1
R/W uint16 0=L
1= m
3
2=US GAL
3= I GAL
4=FT3
5= BBL
6=kg
7= ton
8=US ton
9=lb
d: 227
h: 0x0E3
40228
k-factor
1
R/W uint16 1...9999999
Representation: 0.000010…9999999